Wiring Guide

Wiring a Bell or Buzzer to Netbell-2

Step-by-step instructions for connecting a 12 VDC bell, a 24 VAC extra loud bell or a 24 VAC buzzer to Output 1 on the Netbell-2.

Updated October 30, 2026 2 min read Download PDF
Before You Start

01Before You Start

The bell or buzzer connects to Output 1 on the Netbell-2, which has two terminals. The Netbell-2 switches the power from the bell’s power supply on and off, so the power supply is wired in series with the bell through Output 1.

Device Power supply Polarity
12 VDC bell 12 VDC Matters: follow the wire markings
24 VAC extra loud bell 24 VAC None: either wire can go to either terminal
24 VAC buzzer 24 VAC None: either wire can go to either terminal
Important

When you use the supplied WAGO connectors, insert only the bare copper wire into the slot. Keep the insulation outside the connector.

02Connect a 12 VDC Bell

  1. Find Output 1 on the Netbell-2. It has two terminals.
  2. Connect the negative wire from the bell to one Output 1 terminal.
  3. Connect the negative wire from the 12 VDC power supply (marked with a white stripe) to the other Output 1 terminal.
  4. Connect the positive wire from the bell to the positive wire from the power supply (solid black).
Figure 1Netbell-2 with a 12 VDC bell

03Connect a 24 VAC Extra Loud Bell

A 24 VAC device has no positive or negative side, so either bell wire can go to either connection.

  1. Find Output 1 on the Netbell-2. It has two terminals.
  2. Connect one wire from the bell to one Output 1 terminal.
  3. Connect a two-conductor wire to the AC and AC terminals of the 24 VAC power supply.
  4. Connect one wire from the power supply to the other Output 1 terminal.
  5. Connect the second wire from the bell to the second wire from the power supply.
Figure 2Netbell-2 with a 24 VAC extra loud bell

04Connect a 24 VAC Buzzer

A 24 VAC device has no positive or negative side, so either buzzer wire can go to either connection.

  1. Find Output 1 on the Netbell-2. It has two terminals.
  2. Connect one wire from the buzzer to one Output 1 terminal.
  3. Connect a two-conductor wire to the AC and AC terminals of the 24 VAC power supply.
  4. Connect one wire from the power supply to the other Output 1 terminal.
  5. Connect the second wire from the buzzer to the second wire from the power supply.
Figure 3Netbell-2 with a 24 VAC buzzer

Still stuck? Our support team can help with setup and configuration.

support@linortek.com