Installation and User Manual
VidiMax Display Management System
Install the VidiMax Server and Display Terminal Units, then monitor, control and automate content across your network of displays.
01Hardware Overview
The VidiMax system consists of two hardware components: the VidiMax Server and the VidiMax Display Terminal Unit (DTU). The server is the central controller: it hosts the web interface, manages all connected displays, runs automation tasks and communicates with connected Linortek devices. The Display Terminal Unit is the client device that connects to a screen and renders the content the server sends to it.
This guide covers the physical installation of both components. After completing it, continue with Getting Started to configure the software.
What Is in the Box
VidiMax Server
- VidiMax Server unit (Mini-ITX form factor)
- USB-C power adapter (01-850-00144)
- USB-C to USB-C cable (01-850-00180)
- RJ45 network cable (01-390-00020)
VidiMax Display Terminal Unit (DTU)
- Display Terminal Unit
- HDMI cable
- Ethernet cable (for PoE connection)
A PoE switch or PoE power injector/adapter is required to power the Display Terminal Unit but is not included. See Power over Ethernet (PoE) Requirements.
System Components
| Component | Description |
|---|---|
| VidiMax Server | A compact Mini-ITX PC that acts as the central controller for the entire system. Hosts the web-based management interface, manages all display content and communicates with connected Linortek devices. Can be placed on a desk or shelf, or mounted using a compatible Mini-ITX bracket or enclosure. |
| Display Terminal Unit (DTU) | A compact client device that connects to a display screen via HDMI. Powered over Ethernet (PoE), so no separate power cable is required. Receives content from the VidiMax Server and renders it on the connected screen. |
| Linortek Devices (optional) | Linortek devices from the Netbell, iTrixx and Regular I/O product lines that connect to the VidiMax Server via Ethernet. These are configured separately and are not covered in this guide. |
Deployment Scenarios
VidiMax supports three deployment scenarios. They can also be combined, for example using Interface 1 for remote administration while running displays on a dedicated network through Interface 2.
Scenario A – Standalone (No External Network)
The VidiMax Server operates entirely without connecting to an existing network. The server provides its own DHCP network from its DHCP port (Interface 2), and all display terminals and Linortek devices connect to a PoE switch on that port. The server is managed locally using a display and keyboard/mouse connected directly to the server.
- Best for: environments where connecting to an existing IT network is not desired or not possible.
- Requirements: a display and keyboard/mouse connected directly to the server, and a PoE switch connected to Interface 2 to power DTUs and Linortek devices.
Scenario B – Network Connected
The VidiMax Server connects to your existing LAN via Interface 1 and also uses Interface 2 to provide a dedicated managed network for display terminals and Linortek devices. The server is administered through a web browser on any networked computer. This is the most common deployment for larger installations, where a clean separation between the managed device network and the main LAN is preferred.
- Best for: most installations. Allows remote administration from any networked computer without a dedicated monitor or keyboard at the server.
- Requirements: an available Ethernet port on your network switch or router for Interface 1, and a PoE switch connected to Interface 2 for displays and devices.
Scenarios can be combined. For example, use Interface 1 for remote web administration while Interface 2 provides a dedicated network for displays and devices.
Scenario C – Network Connected, Displays on Main LAN (LAN2 Not Used)
The VidiMax Server connects to your existing LAN via Interface 1 only, and Interface 2 (LAN2) is left unused. Display terminals and Linortek devices are connected to the same LAN as the server and are discovered automatically. This is the simplest setup when your existing network already has PoE switching and all devices can be placed on the same network segment as the server.
- Best for: environments where the existing network already supports PoE and all devices can be placed on the same VLAN or network segment as the server.
- Requirements: an available Ethernet port on your network switch or router for Interface 1, and a PoE-capable switch on the same network to power DTUs and Linortek devices. LAN2 is left disconnected.
02Pre-Installation Checklist
Complete this checklist before beginning installation to make sure you have everything you need.
Site Preparation
- Installation location identified for the VidiMax Server: a stable surface with adequate ventilation.
- Power outlet available within cable reach of the server location.
- Mounting location identified for each Display Terminal Unit.
- Cable routing path planned from the PoE switch to each DTU location.
- Cable routing path planned from the server to the network switch (Scenario B).
Equipment
- VidiMax Server unit received and undamaged.
- USB-C power adapter and USB-C to USB-C cable included and undamaged.
- One Display Terminal Unit per screen received.
- HDMI cable included with each DTU.
- Ethernet cable included for each DTU.
- PoE switch or PoE power injector available, with enough PoE ports for all DTUs and Linortek devices. For Scenario C (displays on main LAN), confirm the existing network switches have available PoE ports.
- Network Ethernet cable available for the Interface 1 uplink (Scenario B).
- Display screens are mounted and their HDMI inputs are accessible.
Network Information (Scenario B)
- IP address range or DHCP availability confirmed with your IT team.
- Available port on your network switch identified for the Interface 1 uplink.
- If using a static IP: static IP address, subnet mask and gateway noted for configuration.
- Firewall or network access policy reviewed, if applicable.
After Installation: Handoff to Configuration
Once all hardware is installed and powered on, the software configuration phase begins. Continue with:
03VidiMax Server Installation
The VidiMax Server is a compact Mini-ITX PC, fanless or low-noise, designed to be installed in a variety of locations, including server rooms, AV closets, back-of-rack spaces, or on a desk or shelf near the installation site.
Hardware Ports
Familiarize yourself with the connectors on the server’s back plate before beginning installation. From left to right they are labeled DB, 5V, USB1, USB2, LAN1, LAN2 and HDMI.
| # | Label | Connector | What it does |
|---|---|---|---|
| 1 | DB |
Micro-USB port | Service and diagnostics connection. Not used in a standard installation. |
| 2 | 5V |
USB-C power port | 5 VDC power input. Connect the included USB-C power adapter with the USB-C to USB-C cable. If a replacement is needed, use a USB-C power adapter rated 2 A at 5 V. |
| 3 | USB1 |
USB-C port | Connect a USB-C keyboard or mouse for local administration. Only needed in Scenario A or for initial setup without a network connection. |
| 4 | USB2 |
USB-A port | Connect a USB keyboard or mouse for local administration. Only needed in Scenario A or for initial setup without a network connection. |
| 5 | LAN1 |
Ethernet – Interface 1 | Uplink to your existing network or the internet. Use it for remote web administration from networked computers. |
| 6 | LAN2 |
Ethernet – Interface 2 | DHCP server for a dedicated device network (optional). Connect the switch for display terminals and Linortek devices here to keep them separate from your main LAN. Not used in Scenario C, where devices are on your existing network and the server finds them through LAN1. |
| 7 | HDMI |
HDMI output (set slightly higher than the other ports) | Local monitor for administering the server itself; this is not a display terminal. Use it in Scenario A or for initial setup without a network connection. |
Placement
The VidiMax Server can be installed on a desk, a shelf or inside an AV cabinet. Choose a location that meets the following requirements:
- Ventilation – make sure there is adequate airflow around the unit. Do not place it in an enclosed space with no airflow, against walls on all sides, or under heavy objects.
- Cable reach – the unit must be within cable reach of a power outlet, your network switch (Scenario B) and the switch that serves the display terminals.
- Access – the unit should be accessible for maintenance, cable management and visual inspection of its indicator lights.
- Environment – install in a dry, indoor location. Avoid excessive dust, moisture, direct sunlight and nearby heat sources.
Operating temperature, humidity limits and physical dimensions are listed in the product specification sheet included in the box.
Server Installation – Step by Step
Step 1 – Position the unit
- Place the VidiMax Server on a stable, flat surface such as a desk, a shelf or the top of an AV rack.
- Leave at least 5 cm (2 in) of clearance on all sides for airflow.
- Orient the unit so all ports are accessible and cables can be routed neatly.
Step 2 – Connect the device switch (Interface 2, DHCP port)
- Connect one end of an Ethernet cable to Interface 2 (
LAN2) on the VidiMax Server. - Connect the other end to the uplink port of the switch that serves your display terminals and Linortek devices.
- That switch’s other ports will later be used to connect Display Terminal Units and Linortek devices.
Do not power on that switch yet. Connect the display terminals first (see Display Terminal Unit Installation), then power everything on in the order described in Power-On Sequence.
Step 3 – Connect to your network (Scenario B only)
- Connect one end of an Ethernet cable to Interface 1 (
LAN1, the uplink port) on the VidiMax Server. - Connect the other end to an available port on your network switch or router.
- The server obtains an IP address from your network’s DHCP server automatically on first boot. A static IP can be configured later through the web interface; see Network Configuration.
Step 4 – Connect a local display and keyboard (Scenario A or initial setup)
Skip this step if you are using Scenario B and will access the server through a web browser on your network.
- Connect a monitor to the server’s
HDMIport with an HDMI cable. - Connect a keyboard and mouse to
USB2(USB-A) andUSB1(USB-C). - For a keyboard or mouse with a USB-A plug on
USB1, use a USB-C to USB-A adapter, or use a keyboard with a built-in touchpad onUSB2.
The display and keyboard connected to the server are for administering the server itself; this is not a display terminal. Do not use the same screen for both purposes.
Step 5 – Connect power
- Connect one end of the USB-C to USB-C cable to the USB-C port on the power adapter, and the other end to the
5Vport on the VidiMax Server. - Plug the power adapter into a grounded power outlet or a UPS (recommended).
- Do not power on yet. Complete the display terminal connections first.
Use the Linortek power adapter supplied. If a replacement is needed, use a USB-C power adapter rated 2 A at 5 V. An adapter with a different rating may damage the hardware and will void the warranty.
Hardware Specifications
| Specification | Value |
|---|---|
| Form factor | Mini-ITX |
| Dimensions (W × D × H) | 10.25 × 8 × 3.25 in (260 × 203 × 83 mm) |
| Weight | 1,470 g (3.2 lb) |
| Power input | 5 V DC via USB-C (labeled 5V); USB-C power adapter and USB-C to USB-C cable included; replacement adapter: USB-C, 2 A at 5 V |
| Power consumption | To be confirmed |
| Operating temperature | 0 – 85 °C |
| Storage temperature | −40 – 125 °C |
| Ethernet ports | 2 × Gigabit Ethernet (RJ-45): LAN1, LAN2 |
| Display output | HDMI |
| USB | 1 × USB-C (USB1); 1 × USB-A (USB2); plus the USB-C power input (5V) and a micro-USB service port (DB) |
Power-On Sequence
Power on the system in this order so the server is ready before the display terminals try to connect:
- Power on the VidiMax Server.
- Wait about 30 seconds for the server to fully boot.
- Power on the switch that serves the display terminals.
- The Display Terminal Units start up and begin connecting to the server automatically.
Server status lights
| Lights | Meaning |
|---|---|
| Both lights orange | The server is powered on. |
| Only the left orange light on, blinking | The server is connected to the network and communicating. |
The Display Terminal Units communicate with the server over the network. If the display terminals start before the server has finished booting, the terminals may show a connection error on first start. This resolves itself once the server is ready; no action is needed.
04Display Terminal Unit Installation
The VidiMax Display Terminal Unit (DTU) is a compact client device that connects to a display screen and renders content sent from the VidiMax Server. Each DTU is powered entirely over its Ethernet cable using Power over Ethernet (PoE), so no separate power supply or outlet is needed at the screen location.
Hardware Ports
| Port | Purpose |
|---|---|
| Ethernet (RJ-45) | Connects the DTU to the network and provides PoE power. This single cable carries both data and power. Connect it to a PoE port on a switch that has network access to the VidiMax Server, either on the dedicated managed network (Interface 2) or on your main LAN (Scenario C). |
| HDMI | Connects the DTU to the display screen. Use the included HDMI cable. The DTU outputs video and audio to the screen over this connection. |
Power over Ethernet (PoE) Requirements
The Display Terminal Unit is powered only over its Ethernet cable, so a PoE power source is required. You have two options.
Option A – PoE switch (recommended for multiple DTUs)
A PoE-capable network switch provides both network connectivity and power to all connected DTUs through a single cable per unit. This is the recommended option when installing two or more display terminals.
- Make sure the switch supports IEEE 802.3af (PoE) or IEEE 802.3at (PoE+). The DTU works with either.
- Connect the switch’s uplink or WAN port to Interface 2 on the VidiMax Server, or to your main network switch if using Scenario C (displays on main LAN).
- Connect each DTU to an available PoE access port on the switch.
Option B – PoE power injector / adapter (for a single DTU)
A PoE power injector (also called a PoE adapter or midspan injector) can power a single DTU without a PoE switch. The injector sits between a standard Ethernet port and the DTU’s Ethernet cable.
- Connect the injector’s data in port to any available Ethernet port on a switch that has network access to the VidiMax Server: either the Interface 2 PoE switch or your main network switch (Scenario C).
- Connect the injector’s data + power out port to the DTU’s Ethernet port.
- Power the injector from a standard power outlet.
Do not try to power the Display Terminal Unit from a non-PoE Ethernet port. The unit requires PoE and will not work without it.
Placement and Mounting
The Display Terminal Unit is designed to be mounted directly behind or underneath the display screen, keeping the installation clean and cable runs short. Most installations use one of these mounting methods:
- Adhesive or bracket mount – mount the DTU to the back or underside of the display frame with adhesive strips or a small shelf bracket.
- Surface mount – place the DTU on a shelf or surface directly below or behind the display if concealment is not required.
Keep the Ethernet cable run between the PoE switch and the DTU as short as practical. The maximum recommended run is 100 m (328 ft), per the 802.3 standard.
DTU Installation – Step by Step
Step 1 – Mount the DTU
- Choose the mounting method that suits your screen and location.
- Place the DTU on a shelf, or secure it to the back of the display frame.
- Make sure the HDMI and Ethernet ports remain accessible.
Step 2 – Connect the HDMI cable
- Connect one end of the included HDMI cable to the HDMI port on the DTU.
- Connect the other end to an available HDMI input on the display screen.
- Note the HDMI input number on the screen (e.g. HDMI 1, HDMI 2). You will select this input in the screen’s menu after powering on.
Step 3 – Connect the Ethernet cable
- Connect one end of the Ethernet cable to the Ethernet port on the DTU.
- Route the cable to the PoE switch. Use cable clips, conduit or cable trays to keep the run tidy and protected.
- Connect the other end to an available PoE port on the switch.
- Do not power on the PoE switch yet. Complete all DTU connections first.
Step 4 – Power on
Once all DTUs are connected, power on the system in the order described in Power-On Sequence:
- Power on the VidiMax Server first and wait 30 seconds for it to fully boot.
- Power on the PoE switch. Each DTU receives power through its Ethernet cable and boots automatically.
- Switch the display screen’s input to the HDMI port connected to the DTU.
- Within 30–60 seconds of the PoE switch powering on, each DTU should connect to the VidiMax Server and show the default Time & Date slate (or its configured default content, if already set up).
If a DTU does not appear in the VidiMax display list after 2–3 minutes, see Troubleshooting: Display Terminal Unit.
DTU Hardware Specifications
| Specification | Value |
|---|---|
| Dimensions (W × D × H) | 109 × 47 × 168 mm |
| Weight | 360 g |
| Power method | Power over Ethernet (PoE) |
| PoE standard | 802.3af / 802.3at |
| Power consumption | To be confirmed |
| Operating temperature | 0 – 85 °C |
| Ethernet port | 1 × 10/100/1000 Mbps (RJ-45) |
| Video output | 1 × HDMI |
05Wiring Diagrams
The diagrams below show the cable connections for Scenarios A and B. Use them as a reference when planning your installation.
Scenario A – Standalone (No External Network)
Scenario B – Network Connected
06Getting Started
Welcome to VidiMax, a display management system designed to help you monitor, control and automate content across a network of digital displays. This manual covers all core features of the system, including the display list, slate configuration, notification templates, automation tasks, National Weather Service integration and the administration menu.
Before you begin, make sure your VidiMax server is powered on and connected to your local network. All configuration is done through a standard web browser. No software installation is required on the device you use to manage the system.
Finding the System IP Address
To access the VidiMax interface you need the server’s IP address. If you do not already know it, use the following method on any Windows computer connected to the same network:
- Open Command Prompt (press
Windows + R, typecmd, pressEnter). - Type the following command and press
Enter:ping vidimax -4 - The reply shows the IP address of the VidiMax server. Make a note of it.
Creating Your Admin Account
On first access, you log in with the default credentials, create your own admin account, and then log in again with it.
- Open a web browser and navigate to the VidiMax server’s IP address (e.g.
https://192.168.1.50). - The browser shows a security warning, such as “Your connection is not private”. Click Advanced › Proceed to the address to continue.
Why the warning appears
VidiMax uses a generic SSL certificate to encrypt the connection. The browser can’t match it to a public website name, so it warns you. The connection is still encrypted, and it is safe to proceed to your VidiMax server’s address.
- Log in with the default credentials: username
admin, passwordadmin. - You are then prompted to create an admin account. Enter the following:
- Username – choose a unique login name.
- Email address – used for account identification.
- Password – choose a strong password and keep it secure.
- Click Create Account.
- Write down your username and password on the Credentials line of the label on the VidiMax Server.
Important
If the username or password is forgotten, contact Linortek support at support@linortek.com to reset them.
- You are prompted to log in again. Log in with the username and password you just created.
All VidiMax accounts are admin accounts, with full access to every feature, including the Admin menu. You can add more accounts later in User Management.
Logging In
On all subsequent visits, navigate to the VidiMax server IP address in your browser. You will see the login screen.
- Enter your Username and Password.
- Click Log In.
Bookmark the system IP address in your browser for quick access. If the server’s IP address changes (for example, after a network reconfiguration), use the ping method above to find it again, or set a static IP through the Admin menu.
System Overview
Once logged in, you will see the main navigation menu. The VidiMax system is organized into the following sections:
| Section | What it does |
|---|---|
| Displays | View and manage all connected display screens. Configure what each display shows by default, view the live push queue, and monitor what is currently playing across all screens. |
| Devices | View and manage connected Linortek devices from the Netbell, iTrixx and Regular I/O product lines, and other network-connected devices. |
| Tasks | Build IF/THEN automation rules that trigger actions based on schedules, weather alerts, device conditions or other events. |
| Slates | Create and manage reusable content slates (text messages, images, alerts and web pages) that can be pushed to displays manually or via automated tasks. |
| Logs | View a complete history of system activity, including user logins, task executions, notifications sent and errors. |
| Database | Connect external systems to the VidiMax PostgreSQL database for data integration and reporting. |
| Admin | Manage users, apply software updates, configure the network, adjust system settings and add remote displays. |
| System Config (Admin) | Network, remote display and date/time settings – see below. |
| Network Settings | Two Ethernet ports: a LAN connection to your existing network, and a secondary connection (DHCP server) that automatically assigns IP addresses to connected devices. |
| Remote Display Settings | Configure remote display connection settings for Azure Blob storage and MQTT communication. |
| Date/Time Settings | Configure the system time zone and daylight saving time settings. |
Recommended First Steps
If you are setting up VidiMax for the first time, follow this sequence to get your system running quickly:
- Log in and confirm you can see the Displays page. Your connected screens should appear automatically.
- Go to Slates and create at least one slate (a basic text or alert message).
- Return to Displays, open a display’s detail panel, and add the slate to its configuration queue.
- Go to Tasks and create your first automation rule if needed (for example, a weather alert task).
- Review the Logs page after a few minutes to confirm the system is running correctly.
07Displays
The Displays page is your central dashboard for monitoring and controlling all connected display screens. Every VidiMax client device that connects to the server is automatically discovered and listed here. From this page you can see what is playing on each screen, manage push queues and configure each display’s default content.
Active Pushes
Above the display list, the Active Pushes panel gives a system-wide view of all notification slates currently being pushed across your entire network of displays. The panel groups pushes by template name, so if the same Storm Warning slate is playing on 18 displays, it appears as a single row rather than 18 separate entries. This keeps the panel useful even in large deployments with 50–100+ screens.
The top bar of the panel is always visible, even when the panel is collapsed. It shows:
- A pulsing red dot indicating active pushes are in progress.
- The title “Active Pushes”.
- A priority count breakdown, for example: P1 Critical · 18 displays | P2 High · 4 displays | P3 Medium · 9 displays.
- The total number of active push entries across all displays.
Click anywhere on the summary bar to expand or collapse the panel body. Each row in the expanded panel represents one unique slate being pushed, regardless of how many displays are showing it. Each group row displays:
- The slate name.
- A display count pill showing how many screens are playing it (with a pulsing green dot).
- The priority level badge (color-coded P1–P5).
- The source of the push: task for automated task actions, manual for pushes sent directly from the Slates page.
- A Dismiss all N button that removes this slate from every display showing it simultaneously.
Dismiss All cannot be undone. All queued and playing pushes are removed from every display. Displays immediately return to their slideshow or default slate configuration.
Filtering and Sorting
Above the display list, use the Filter search box to find displays by name. The Sort By dropdown sorts by display name, status or temperature. Use Show All to remove any active filters.
The Display List
The display list shows all known display devices in a table. Each row represents one screen:
| Column | Description |
|---|---|
| Display Name | The name assigned to this screen. By default, a new display is named Display followed by its MAC address. Click the name or the edit icon to rename it. Use descriptive names, for example “Lobby East”, “Meeting Room 2F” or “Reception Monitor”. |
| IP Address | The local network IP address of the display client. Shows N/A if the display is on the VidiMax-managed network without a routable IP. |
| MAC Address | The hardware MAC address of the display client. Useful for identifying devices on the network or in router DHCP tables. |
| Status | A green dot means the display is online; a grey dot means it is offline. The device temperature is shown below the status dot. |
| Actions | The eye icon opens the full Display Details panel for that screen. |
08Display Details
Click any display row to open the Display Details panel. The panel is divided into two sections: Basic Information and Slate Configuration.
Basic Information
This section shows the technical details of the display device. The Display Name can be edited by clicking it. All other fields are read-only system values:
- Display Name – editable. Defaults to “Display” followed by the MAC address. Click to rename.
- IP Address – the device’s local network address.
- MAC Address – the hardware identifier.
- Status – Active (online) or Inactive (offline).
- Resolution – the screen’s pixel resolution (e.g. 1920×1080).
- Temperature – the internal device temperature in Fahrenheit and Celsius. High temperatures may indicate the need for better ventilation.
- Certificate CN – the device certificate client name, used for remote display configuration.
- Thumbprint – the certificate fingerprint for remote display verification.
Display Settings
- Power – ON/OFF switch. Works only if the TV/display supports CEC.
- Time Zone – set a specific time zone for the display. By default it follows the VidiMax server’s time configuration.
Slate Configuration
This section controls what the display shows when no push notification is active. Think of it as the display’s idle or background content.
Display Mode
Choose how the display behaves when idle:
- Single Slate – the display shows one selected slate continuously on loop. Use this when a specific piece of content should always be visible, for example a clock or a lobby welcome message.
- Slideshow – the display cycles through a queue of slates in order, each playing for its configured duration before advancing. Use this for varied content: announcements, menus, event listings and a clock combined in rotation.
Allow Interruptions
This toggle controls whether pushed notifications can override the idle content:
- On (default) – pushed slates from tasks or manual sends appear on this display, interrupting the slideshow or single slate. This is the standard setting for most displays.
- Off – no push notification will ever override this display. It keeps showing its configured content regardless of any task or manual send that targets it. Use this for dedicated displays, for example a reception screen that must always show a specific welcome message.
When Allow Interruptions is turned off, this display is unaffected by weather alert tasks. Make sure this is intentional before disabling it.
Slate Queue
The slate queue is the list of slates that make up the display’s idle content. In Single Slate mode, only the first slate (or the one marked Default) is shown. In Slideshow mode, all slates in the queue cycle in order.
| Column | Description |
|---|---|
| # | The position in the queue. In Slideshow mode, slates cycle from 1 upward and then repeat from the beginning. |
| Slate | The name of the notification template. Built-in slates (such as Time & Date) carry a “built-in” label. |
| Duration | How many seconds this slate plays before advancing to the next one. Minimum 5 seconds. |
| Status | “Now Playing” (pulsing green dot) for the slate currently on screen. “Default” (blue badge) for the slate that displays on power-on. |
| Actions | ↑ move up, ↓ move down, Set Default to mark as the boot slate, × to remove. |
Setting a Default Slate
The Default slate is what appears on the display when it first powers on, before the slideshow begins cycling. To change it:
- Locate the slate you want as the default in the queue table.
- Click Set Default in its Actions column.
- The blue Default badge moves to that row.
- Click Save Changes to apply.
Only one slate can be the default at a time. The Set Default button is disabled on whichever row currently holds the Default badge.
Adding a Slate to the Queue
Click + Add Slate below the queue table. A picker opens showing all available slate templates. The built-in Time & Date slate is always available, regardless of which templates you have created. The selected slate is added to the bottom of the queue; use the ↑ and ↓ arrows to reposition it.
Built-in Time & Date Slate
VidiMax includes a built-in Time & Date screen that shows the current time and date. This is the factory default content that displays show when no other configuration has been applied.
Now Playing (per Display)
The push queue appears at the top of the Display Details panel, above Slate Configuration. It shows all notification slates pushed to this specific display, by an automated task or a manual send, that are currently playing or waiting to play.
Understanding the Push Queue
Unlike the idle slideshow content, pushed notifications are temporary. They play for a set duration and then the display returns to its normal content. The push queue is ordered by priority: higher-priority items play first regardless of when they were sent.
- The currently playing item is always in position 1, shown with a pulsing green dot and a live progress bar counting down the remaining time.
- Waiting items appear below in the order they will play, at reduced opacity with a grey Waiting badge.
- Each item shows its slate name, priority level, duration and source (task or manual send).
Dismissing and Removing Items
- Dismiss (playing item) – ends the current slate immediately and advances to the next item in the queue. If the queue is then empty, the display returns to its slideshow.
- × Remove (waiting item) – cancels a queued item before it plays. The currently playing slate is not affected.
Use the global Dismiss All button on the Displays page to clear pushed content from all displays at once, for example after a weather alert has passed.
09Slate Priority System
Every notification pushed to a display, whether triggered automatically by a task or sent manually, carries a priority level. Priority decides what happens when several notifications arrive at the same display at the same time. Rather than the last-sent notification always winning, VidiMax uses a structured priority queue so the most important content always reaches the screen first.
Why Priority Matters
Consider a scheduled Morning Announcements slate playing on all lobby displays when the National Weather Service issues a tornado warning. Without priority, the announcements would keep playing until their scheduled time ended, or until someone intervened manually. With priority, the tornado warning, configured as P1 Critical, immediately interrupts the announcements (configured at P3 Medium or lower) and takes over all displays. When the warning slate’s duration ends, the announcements resume automatically.
You never have to manage competing content by hand. Every piece of content has a clearly defined rank, and the system enforces it automatically and consistently.
Priority Levels
| Level | Name | Interruption behavior | Typical use |
|---|---|---|---|
| P1 | Critical | Cannot be interrupted by anything. Every lower-priority slate in every queue waits until this finishes. | Emergency alerts, tornado/fire warnings |
| P2 | High | Interrupts P3, P4 and P5. Waits if P1 is currently playing. | Manual urgent pushes, important announcements |
| P3 | Medium | Interrupts P4 and P5. Waits if P1 or P2 is playing. | Scheduled announcements, weather advisories |
| P4 | Standard | Interrupts P5 only. Waits if P1, P2 or P3 is playing. | Routine content, informational messages |
| P5 | Low | Never interrupts anything. Always waits at the back of the queue. | Background or decorative content |
Queue Rules
| Scenario | What happens |
|---|---|
| Higher-priority push arrives while lower-priority is playing | The playing slate is interrupted immediately and the higher-priority slate begins playing. The interrupted slate moves to the front of the waiting queue and plays next. |
| Lower-priority push arrives while higher-priority is playing | The new slate joins the queue and waits. It will not play until the current item and any other higher-priority items have finished. |
| Two slates of equal priority arrive simultaneously | They queue in the order received, first in, first out (FIFO). Neither interrupts the other. |
| The push queue empties | The display immediately and automatically returns to its configured slideshow or default single slate. |
Duration
Every pushed slate has a duration: the number of seconds it plays before automatically clearing and advancing the queue. Duration is set when the push is created, either in the Task action settings or in the Send Notification window when sending manually.
- There is no maximum, but very long durations on high-priority slates block all lower-priority content for the entire duration.
- Operators can always end a playing slate early with Dismiss in the Display Details panel or the Active Pushes panel.
A very short duration (under 10 seconds) on an emergency alert may not give viewers enough time to read and respond. Recommended minimum for emergency content: 60 seconds.
10Slates
Slate templates are the content pieces shown on your screens. A template defines what the audience sees: a text message, an image, a weather alert, a live device readout or a custom web page. You create templates once and reuse them across tasks, displays and manual sends.
Create your templates before setting up tasks, since tasks reference templates by name when configuring their actions.
The Templates Page
Navigate to Slates from the main menu. The page lists all existing templates in a table with these columns:
- Preview – a thumbnail of the template’s appearance.
- Name – the template’s display name.
- Type – the notification type (Alert, Message, Image, etc.).
- Actions – icons to edit/preview, add to a display’s slideshow or send once, and delete.
Click Add Template in the top right corner to create a new one.
Creating a Template
After clicking Add Template, the template editor opens. Work through the following fields.
Template Name
Give the template a clear, descriptive name. You will reference this name when configuring task actions, so names like “Storm Warning”, “Morning Announcements” or “Cafeteria Menu – Monday” work better than “Template 1”.
Notification Type
Select the type of content this template will display. Each type has its own configuration options:
| Type | Description and configuration |
|---|---|
| Alert | A single-line message designed for high visibility. Ideal for weather warnings, safety notices and urgent announcements. Options: message text (bold, italic, underline, font size and color), background color, and vertical position (top / center / bottom). HTML Mode replaces the text editor with a full HTML code editor: paste your complete HTML document (with all CSS and JavaScript embedded) and click Refresh Preview to verify before saving. |
| Message | A structured message with a Sender name, a Heading and a Body. Suitable for internal announcements, memos or notices. HTML Mode is also available for fully custom layouts; all CSS and JavaScript must be embedded in the HTML document, as external file references will not load. |
| Image | Displays a static image full screen. Useful for schedules, maps, posters or branded content. Upload an image file (common formats supported). |
| Device Info | Shows live data from a connected Linortek device in real time, for dashboards of sensor readings, relay states or device status. Select the device, then the properties to display. HTML Mode is also available; all CSS and JavaScript must be embedded in the HTML document. |
Want a finished design without writing HTML? Copy one from VidiMax Ready-Made Screens, change the highlighted words to your own, and paste it into a slate in HTML Mode.
Saving and Previewing
Use the Preview button (top right of the editor) to see exactly how the template will look on screen before saving. Use the Save icon to save the template and the Download icon to export its configuration.
Related guides
- Ready-made screens to copy (HTML samples)
- Create YouTube video slates
- Create custom Device Info slates
- Display live data from a spreadsheet on your server or PC
Editing and Deleting Templates
On the Templates page, click the edit icon (pencil) in the Actions column to reopen the editor for any template. All settings can be changed and saved again.
To delete a template, click the delete icon. If an active task references the template, you will be warned before deletion. Deleting a template that tasks depend on breaks those task actions.
Renaming a template does not update task actions that reference it by the old name. After renaming, check and update any tasks that use that template.
Sending a Template Manually or Adding It to a Slideshow
Any template can be pushed to one or more displays immediately, or added to a display’s slideshow, without creating a task. This is useful for one-off announcements, testing, or updating a slideshow without opening a particular display.
- On the Slates page, find the template you want to send or add.
- Click the send icon (paper plane) in the Actions column.
- The Send Notification window opens, showing the template name at the top for confirmation.
- Select Send Now or Add to Slideshow.
- Under Select Displays, check each display that should receive the notification. For Add to Slideshow, select one display at a time.
- Set the Duration: the number of seconds the slate plays on each selected display before clearing.
- Send Now only: select the Priority (P1–P5). Manual pushes default to P2 High, which interrupts most routine content but waits behind any active P1 emergency alert.
- Click Send to dispatch the notification immediately, or Add to save it to the selected display’s slideshow.
11Tasks & Automation
The Tasks page is where you define automated rules that run without manual intervention. Each task uses an IF / THEN structure: when a specified condition (event) occurs, the system executes one or more responses (actions). A task can be as simple as pushing a daily announcement at 8:00 AM, or as complex as responding to a National Weather Service warning by alerting every display, ringing outdoor bells and triggering audio notifications at once.
Tasks run continuously in the background while they are enabled. You can have as many tasks as needed, and each one operates independently.
Creating a Task
- Navigate to the Tasks page.
- Click Add Task in the top right corner.
- The Task Builder opens. Enter a Task Name; use something descriptive like “Morning Announcements – Weekdays” or “Tornado Warning – All Buildings”.
- Optionally enter a Description explaining what the task does and when it was created.
- Add one or more Events to define the trigger conditions.
- If you have multiple events, set the AND / OR logic between them.
- Add one or more Actions to define what happens when the task fires.
- Click Save Task. The task is active immediately.
The Task Enabled Checkbox
At the top of the Task Builder is a Task Enabled checkbox, checked by default. When checked, the task runs automatically. When unchecked, the task is saved but paused and will not fire until re-enabled.
To pause a task temporarily without deleting it:
- Open the task with the Edit button.
- Uncheck Task Enabled.
- Click Save Task.
To resume it, repeat the process and check the box again. This is much faster than recreating the task from scratch.
Event Types
Events are the trigger conditions for a task. Each task can have one or more events. Click + Add Event to add event rows; click the chevron on a row to configure it.
| Event type | Description and configuration |
|---|---|
| Time | Triggers at a specific time each day. Enter the time in HH:MM (24-hour) format. Use *:MM to trigger every hour at that minute; for example, *:00 fires at the top of every hour. |
| Periodic | Triggers repeatedly on a fixed interval. Enter an interval value and select the unit: Seconds, Minutes, Hours or Days. For example, value 30 with unit Minutes fires every 30 minutes from the moment the task is saved. |
| Weekday | Triggers on a specific day of the week, optionally at a specific time. Select the day (Monday through Sunday) and optionally enter a time in HH:MM format. If left blank, the task fires at midnight on that day. |
| Weather Alert | Triggers when the National Weather Service issues a qualifying alert for your selected area. Select State, one or more Counties, one or more Alert Types, and the minimum Severity level. The VidiMax server polls weather.gov every 2 minutes. |
| Device | Triggers when a property on a connected Linortek device meets a condition. Select the device, then the property to monitor (for example, temperature or relay state), and configure the threshold. |
AND / OR Logic Between Events
When a task has two or more events, choose how they combine with the AND / OR toggle that appears between event rows.
- AND – all events must be true at the same time for the task to fire. For example: IF it is a weekday AND IF it is 8:00 AM.
- OR – any single event being true triggers the task. For example: IF a Tornado Warning is issued OR IF a Severe Thunderstorm Warning is issued.
Action Types
Actions are what VidiMax does when a task fires. A single task can have multiple actions that all execute simultaneously. Click + Add Action to add action rows.
| Action type | Description and configuration |
|---|---|
| Slate | Pushes a slate to one or more displays. Select the notification template (slate), the target displays, the duration in seconds and the priority level (P1–P5). A hint below the priority selector explains each level. Weather alert actions should generally use P1 Critical so no other content can block them. |
| Cancel Slate | Cancels the currently playing slate and plays the next queued slate, or the home slate if the queue is empty. |
| Relay | Turns a relay on a connected Linortek device ON or OFF. Select the device (identified by hostname, or IP address if there are several), the relay number and the state. Relay ON typically activates bells, tone generators, strobes or other wired equipment. |
| Log | Writes a custom message to the system log. Select a log level (Info, Warning, Error) and enter the message. Useful for audit trails and for confirming that a task fired as expected. |
Configuring Priority and Duration on a Slate Action
Every Slate action has two fields that control how the push behaves on the display.
Duration
Enter the number of seconds the slate should remain on screen. The minimum is 5 seconds.
- Emergency alerts: 60–180 seconds gives viewers enough time to see and respond.
- Routine announcements: 30–60 seconds is typical for slideshow-style rotation.
- Very long durations on high-priority slates block all lower-priority content for that entire time.
Priority
Click one of the five buttons (P1 through P5). The selected button highlights in its priority color, and a description below explains its behavior:
- P1Critical – cannot be interrupted. All lower-priority slates wait.
- P2High – interrupts P3, P4 and P5. Waits if P1 is playing.
- P3Medium – interrupts P4 and P5. Waits if P1 or P2 is playing.
- P4Standard – interrupts P5 only. Waits if P1–P3 is playing.
- P5Low – never interrupts. Always waits for everything else to finish.
Example Tasks
Example 1: Daily Morning Announcement
| Field | Value |
|---|---|
| Task Name | Morning Announcements – Weekdays |
| Event 1 | Weekday – Monday, Wednesday, time 08:00 |
| Action | Slate – “Morning Announcements” template, all displays, duration 60 s, priority P3 Medium |
Example 2: Temperature Alert
| Field | Value |
|---|---|
| Task Name | Server Room Overheating Alert |
| Event | Device – Server Room Sensor, temperature > 96°F |
| Action 1 | Slate – “Temperature Alert” template, IT Office Display, duration 300 s, priority P2 High |
| Action 2 | Log – level Warning, message “Server room temperature threshold exceeded.” |
| Logic | OR (fires if either device reads a high temperature) |
12Devices
The Devices page lists all Linortek network devices reachable on the VidiMax network, from the Netbell, iTrixx and Regular I/O product lines. They are discovered automatically when connected to the same LAN segment as the VidiMax server.
Device List
Each device in the list shows its name, IP address, MAC address and online status.
From the list you can:
- Pin a device to the top of the list with the + icon, and unpin it with the – icon. Useful for devices you check often.
- Show or hide offline devices with the toggle. Offline devices stay listed with their last-known information; hiding them reduces clutter in large deployments.
- Search and filter by name, IP address, MAC address or status with the filter bar.
- Edit a device name with the edit icon. Clear, location-based names (for example “Netbell-2 – Building A Entrance”) make relay configuration in tasks much easier.
Adding Devices Manually
Devices on the same LAN segment as the VidiMax server are discovered automatically. The Add Manually option is for third-party IoT devices that are not auto-discovered. This feature is currently in development; check the release notes for availability.
If a Linortek device does not appear in the list, confirm it is powered on and connected to the same network segment as the VidiMax server. Check that it has a valid IP address by opening its web interface directly.
13Logs
The Logs page provides a complete, time-stamped history of all activity in the VidiMax system. Logs are generated automatically and cannot be edited. They are essential for troubleshooting, compliance and confirming that automated tasks run as expected.
What Is Logged
- User activity – logins, logouts, failed login attempts and account changes.
- Task execution – every time a task fires, with the task name, timestamp and actions executed.
- Notifications sent – every slate pushed to displays, including target displays and duration.
- Relay activations – every relay action executed by a task.
- System events – software updates, configuration changes and device connection/disconnection events.
- Custom log entries – messages written by Log actions in tasks.
- Errors and warnings – any system errors or conditions that need attention.
Filtering and Viewing Logs
Filter the log table by log type (Info, Warning, Error), by date range or by keyword. Use the search bar to find entries for a specific task, display, device or user.
Set the auto-refresh interval to keep the log view updating in real time during active monitoring. This is particularly useful during testing, for example when verifying that a weather alert task fires correctly after setup.
Downloading Logs
Click Download to export the current log view for offline analysis, record-keeping or sharing with support staff. Available in .txt and .csv format.
14Database Integration
VidiMax stores its system data in a PostgreSQL database. The Database page lets external platforms and reporting tools connect to this database and read its data for integration, analytics or custom dashboards.
Configuration
- Configure the update interval: how often VidiMax writes updated data to the database tables used by external connections.
- Enable external connections to allow third-party systems to read data.
- Copy the Provisioning Info to get the connection string and credentials needed to connect an external tool.
Use Cases
- Pulling notification and task activity into a central reporting dashboard.
- Integrating display status data with a building management system.
Database access grants read permission to all system data. Only give provisioning information to trusted systems and administrators. Rotate credentials if a third-party integration is decommissioned.
16System Workflow Overview
- Users log in with their credentials. All accounts have full access to every menu.
- Linortek devices and VidiMax display clients on the network are discovered automatically.
- The Displays page shows the real-time status of all screens. Active pushes are visible in the Active Pushes panel.
- Slate templates are created for all content types needed: alerts, announcements, menus and so on.
- Display configurations are set: each screen’s default content, slideshow queue, durations and default slate.
- Tasks are built to automate content delivery: scheduled announcements, weather alerts and device-triggered responses.
- The Logs page is reviewed periodically to confirm tasks are running correctly and to audit system activity.
17Troubleshooting
Use the tables below to diagnose and resolve common installation issues. If a problem is not listed or the suggested resolution does not help, contact your VidiMax distributor or support@linortek.com.
VidiMax Server
| Symptom | Check / resolution |
|---|---|
| Server does not power on | Confirm the USB-C to USB-C cable is fully seated in both the power adapter and the 5V port, and the adapter is plugged in. Confirm the outlet is live by testing it with another device. Confirm the supplied Linortek power adapter, or a USB-C replacement rated 2 A at 5 V, is being used. When powered, both status lights turn orange. |
| Server boots but cannot be reached on the network (Scenario B) | Confirm Interface 1 (LAN1) is connected to your network switch or router. When the server is communicating, only the left orange light is on and blinking. Check that your network’s DHCP server is active and has available addresses. Connect a monitor and keyboard directly to find the assigned IP address. If using a static IP, verify the address, subnet mask and gateway in the network configuration. |
| Web interface is not accessible from a browser | Check you are entering the correct IP address, including the https:// prefix. Confirm your computer is on the same network as the server. Clear the browser cache or try a different browser. Confirm the server has fully booted (allow up to 1 minute after power on). |
| PoE switch on Interface 2 receives no DHCP addresses | Confirm the server was fully booted before the PoE switch was powered on. Go to Admin › System Config › Network Configuration › DHCP Server and confirm Enable DHCP Server is checked and the DHCP range is set. Click Save if you make changes and allow 30 seconds. |
| Local display (connected directly to the server) shows no output | Confirm the cable is in the server’s HDMI port. Confirm the display is set to the correct input. Try a different cable. Allow up to 90 seconds after power on for the display output to start. |
Display Terminal Unit
| Symptom | Check / resolution |
|---|---|
| DTU does not power on (no indicator light, no HDMI output) | Confirm the Ethernet cable is in a PoE-capable port on the switch and the PoE switch is powered on. Try a different PoE port. Verify the switch supports PoE (802.3af) or PoE+ (802.3at). Try a different Ethernet cable. |
| DTU powers on but the screen shows no picture | Confirm the HDMI cable is connected at both ends and the screen’s input is set to the correct HDMI port. Try a different HDMI cable, or a different HDMI input on the screen. |
| DTU does not appear in the VidiMax display list | Confirm the PoE switch has network connectivity to the VidiMax Server, either through Interface 2 (LAN2) or through the main LAN (Scenario C). Allow 2–3 minutes after the PoE switch powers on. If using Interface 2, confirm the server’s DHCP server is active (Admin › Network Configuration › DHCP Server). If using Scenario C, confirm your main network’s DHCP server is assigning addresses. Check the server’s Logs page for connection events. |
| DTU appears offline in the display list | Check the Ethernet cable at both the DTU and the PoE switch port. Confirm the switch port is active, or try a different PoE port. Reboot the DTU by disconnecting and reconnecting the Ethernet cable. |
| DTU connects but shows a black screen or an error message | The DTU has connected to the server but no content has been configured yet. This is expected on a new installation. Log in to the VidiMax web interface and set the display’s default slate; see Displays. |
| Only some DTUs appear in the list | Check that the DHCP address range (Admin › Network Configuration › DHCP Server) has enough addresses for all devices. For example, 10.0.0.10–10.0.0.100 supports up to 91 devices. Extend the range if needed, and confirm every DTU is in a PoE port (not a non-PoE port) on the switch. |
General Network Issues
| Symptom | Check / resolution |
|---|---|
| Linortek devices not discovered on the Devices page | Confirm the device is on the same network as the VidiMax Server: connected to the Interface 2 PoE switch, or on the main LAN (Scenario C). Confirm it is powered on and its indicator lights show a valid network connection. Allow 1–2 minutes after booting. Check the device’s own web interface by opening its IP address from a computer on the same LAN. |
| NWS weather alerts not triggering | Weather alert polling requires internet access on the VidiMax Server. In Scenario B, confirm Interface 1 is connected and the server has a valid gateway. Go to Admin › Network Configuration › LAN and verify the Gateway field is filled in. |
AAppendix: Pre-Deployment Checklist
Use this checklist before going live with VidiMax in a production environment.
User Access & Permissions
- Create a test user account and confirm login works with the correct credentials.
- Test SSH access for any users who require it.
- Make sure every account uses a strong password.
- Write the login username and password on the Credentials line of the server label.
Displays
- All display clients appear in the Displays list with a green online status.
- Each display has a descriptive name.
- Slate queues are configured for each display (duration, order, default slate).
- Display mode (Single Slate or Slideshow) is set correctly for each screen.
- Allow Interruptions is set correctly: on for displays that should receive emergency alerts.
Slates
- At least one slate exists for each type of content to be displayed.
- Weather alert slates exist for each alert type being monitored.
- Custom HTML slates have been previewed and render correctly.
Tasks
- All scheduled tasks have been created and tested.
- Weather alert tasks use the correct state, counties, alert types and severity.
- Priority levels are set correctly on all Slate actions.
- Relay actions reference the correct device and relay number.
- Task Enabled is checked for all tasks that should be active.
Devices
- All Linortek devices appear in the Devices list with online status.
- Relay assignments are documented for each device.
- Relay actions in tasks have been tested to confirm the correct device and relay activate.
Network
- The VidiMax server has a static IP address (recommended for production).
- All display clients and Linortek devices are on the correct network segment.
- The server has internet access for NWS polling (if using weather alerts).
Final Verification
- Trigger at least one task manually or through a test event and confirm all actions execute.
- Confirm the push appears on the targeted displays with the correct slate and priority.
- Check the Logs page to confirm the test event was recorded.
- Dismiss the test push and confirm displays return to their configured default content.
Still stuck? Our support team can help with setup and configuration.
