Before You Start

01Before You Start

This page has two wiring diagrams: the Netbell-Ultra300, which switches the bells through external step-up relays, and the Netbell-Ultra-E, which switches them directly. Each diagram shows two groups of three 12 V bells wired in parallel, with a separate power supply for each group and a push button for manual ringing.

Note

The wiring samples are for demonstration only. You can extend the wires as needed during installation.

Wire gauge Maximum distance from the controller
16 AWG Up to 500 ft, with the supplied power supply
Thicker wire (14 or 12 AWG) Longer runs are possible
Important

When you use the supplied WAGO connectors, insert only the bare copper wire into the slot. Keep the insulation outside the connector.

02Netbell-Ultra300 with Step-Up Relays

The Netbell-Ultra300 drives two step-up relays, and each relay switches the power to one group of bells.

  • Netbell-Ultra300: powered by a 12 V, 1 A supply.
  • Step-up relays: the coil terminals (A1, A2) connect to the Ultra300’s relay outputs R1 and R2 and its V terminal. The contacts (11, 14) switch the bell power.
  • Bells: two groups of three bells in parallel. Each group has its own 12 V, 4 A power supply, wired through one relay’s contacts.
  • Button: connected to input IN1 (terminals C and A).
Warning

Make sure each step-up relay’s rated current is higher than the total current of the bells it switches. Choose the relays before installation to avoid overloading them.

Figure 1Wiring two step-up relays to the Netbell-Ultra300

03Netbell-Ultra-E

The Netbell-Ultra-E switches the bells directly, so no external relays are needed.

  • Netbell-Ultra-E: powered by a 12 V, 1 A supply on the Power connector.
  • Bells: two groups of three bells in parallel, each with its own 12 V, 4 A power supply. One group connects to OUT1 and the other to OUT2.
  • Button: connected to the DIN connector.
Figure 2Wiring low-voltage bells to the Netbell-Ultra-E

Still stuck? Our support team can help with setup and configuration.