User Manual

Netbell SIP Speakers WM-042S · CM-600S · H30-709S

Install, network and configure Netbell VoIP SIP/multicast speakers for live paging and emergency notifications from your phone system.

Updated February 3, 2026 6 min read Download PDF
Overview

01Overview

Figure 1Netbell SIP speakers

Netbell VoIP SIP/multicast speakers are a cost-effective indoor paging solution with Power over Ethernet (PoE 802.3af) and Voice over IP (VoIP). They are designed for offices, schools and medium-sized warehouses with ceilings over 20 ft, where horn speakers are not required and hallways do not need forward-focused coverage.

The speakers integrate with VoIP phone systems for live paging, emergency notifications and other mass messages, and support multicast and broadcast audio from a single endpoint to many speakers at once.

Model Type Power
Netbell-WM-042S Wall-mount speaker 12/24 VDC or PoE · 20 W
Netbell-CM-600S Ceiling speaker 12/24 VDC or PoE · 30 W
Netbell-H30-709S Horn speaker 12/24 VDC or PoE · 30 W

02What’s in the Box

Item Qty
SIP speaker 1
Waterproof cap 1
Mounting bracket set (WM-042S only) 1
Installation drawing 1

03Preparation for Installation

For the best audio quality, we recommend a dedicated VLAN for the speakers, using network equipment that supports multicast. Netbell SIP speakers support PoE/PoE+, and a properly configured network makes installation smooth.

Network Requirements

  • The speakers and the PC running the SIP Config Tool must be on the same LAN.
  • PoE/PoE+ switch ports, with enough switch capacity for the power load of all devices.
  • Minimum CAT5 cable, at most 100 m (328 ft) from each device to the switch.
  • Port 5060 (UDP/TCP, SIP signaling) open on your router or firewall.
  • Router: PIM is required if multicast traffic must pass through multiple routers.
  • Switch: should support IGMP snooping to prevent multicast flooding.

Pre-Installation Planning

We strongly recommend configuring all speakers before installing them. It significantly reduces installation time, minimizes errors and simplifies troubleshooting, especially across larger facilities.

  • Create a network plan. Document your IP addressing scheme so all devices have compatible settings (subnet mask, gateway, etc.).
  • Assign static IP addresses. Configure and document a static IP for every device, to avoid problems caused by changing DHCP addresses.
  • Keep a spreadsheet of device numbers and names, IP addresses, installation locations and any special settings.
  • Test every speaker while it is easy to reach, before mounting it somewhere hard to access.
  • Mount each speaker following the installation drawing supplied with it.

Powering the Speaker

Connect the speaker to your PoE network with a CAT5/5e/6 cable. If PoE is not available, use a 12/24 VDC power adapter (not supplied).

Warning

Do not use PoE and a power adapter at the same time.

Once powered, the green LED blinks and the blue LED stays solid: the speaker is ready to be discovered.

04Installing the SIP Config Tool

Download the SIP Config Tool from Support Programming:

  • 64-bit installer (recommended): run it and follow the prompts.
  • ZIP package: extract it, keep all files together (do not move or delete any), and double-click the .exe.

If Windows shows “Windows protected your PC”, click More info → Run anyway.

05Configuring the Speaker

Setting the Device IP

  1. In the SIP Config Tool, click Search Devices.
  2. When the speaker appears, check its IP address matches your network. The default is 192.168.1.xxx.
  3. If not, select the speaker (it highlights blue) and enter the correct IP Address, Subnet Mask and Gateway under Basic Equipment Parameters at the top.
  4. Click Save, wait about 10 seconds, and click Search Devices again.
  5. Double-click the speaker in the list. Your default browser opens its login page.
Figure 2SIP Config Tool

Logging In

Log in with the default credentials: username admin, password 123456. If the page doesn’t load, check the IP configuration again.

Figure 3Login page

Checking Network Settings

Once logged in, check the Primary and Secondary DNS addresses match your network. To change them, go to the Network page, adjust and save. Then continue to the SIP Settings page.

Figure 4System Overview

Entering the SIP Account

On the SIP Settings page, enter the details from your VoIP system administrator:

Field Value
User Account Paging account username
Password Account password
Display name Shown on your network
Server address SIP domain or registrar
Server port Usually 5060
Outbound proxy address and port If required
Authentication User Authorization ID, if required

Click Save, then Logout and log back in to apply.

Figure 5Example SIP settings
Important

After logging back in, the System Overview should show Server Status: Connected and your SIP server address. If not, check your SIP credentials and DNS settings.

Session Audio Settings

Open Work Settings → Intercom:

Setting Value
Input Channel Leave at MIC
Input Gain (Volume) Gain for intercom
AEC Level Optional echo/noise cancellation
Auto Answer 0 (paging/intercom starts automatically)
Ring Volume Ring volume for intercom
Talk Volume Set for clear audio (intercom and paging)
Codec priority Enable all three, in this order: G.722 (preferred, if supported), G.711u (most compatible; recommended in the U.S.), G.711a (European systems).

Forwarding Audio (RTP Unicast, Multicast, Broadcast)

Each speaker can forward audio to one RTP address. On the same page:

  1. Enable Remote Audio Forwarding.
  2. Set Protocol Type to RTP.
  3. Enter the target address (see the table), then click Save.
  4. Log out and log back in to apply.
Target Address
Unicast <IP address>:<port>
Multicast <multicast address>:<port>, multicast range 224.0.0.1 – 239.255.255.254
Broadcast 255.255.255.255:<port>

Ports can be 1024–65535.

Figure 6Remote Audio Forwarding

Receiving Audio (RTP)

Each speaker can receive audio from up to ten RTP addresses. Open Work Settings → Multicast, enter up to 10 addresses, and set Play Volume (1–100).

Figure 7Work Settings › Multicast

06Security and Maintenance

Changing the Password

  1. Open Advanced Settings → Security.
  2. Enter and confirm the new password, and save.
  3. Log out to confirm.
Tip

Change the default password (123456) on every speaker before installation.

Figure 8Advanced Settings › Security

Upgrade, Reset or Reboot

Open Advanced Settings → Maintenance:

  • Upgrade: click Choose File, select the firmware, click Upgrade, then Reboot. Check the new version on the Maintenance page.
  • Reboot: click Reboot.
Warning

Reset restores factory defaults and permanently erases all your settings.

Figure 9Advanced Settings › Maintenance

07Specifications

Audio

Parameter H30-709S WM-042S CM-600S
Codec G.711u (PCMU) 8 kHz · G.711a (PCMA) 8 kHz · G.722 16 kHz
Max SPL 122 dB 100 dB 100 dB
Frequency response 350 Hz – 15 kHz 85 Hz – 20 kHz 85 Hz – 20 kHz
Frequency range 85 Hz – 2 kHz +10 dB; 400 Hz – 20 kHz +20 dB
Harmonic distortion ≤10% @ 1 kHz – 20 kHz
Signal-to-noise ratio 109 ±3 dB 91 ±3 dB 91 ±3 dB
Amplifier Built-in 30 W Built-in 20 W Built-in 30 W

Network (all models)

Parameter Specification
Security Password protection, IP address filtering, digest authentication
Network protocols SIP, HTTP, IPv4, RTP, RTCP, UDP, DNS, ARP
Network interface 10/100 Base-TX, RJ45
VoIP 1 SIP account, SIP direct IP call, RTP unicast/multicast/broadcast; codecs G.722, PCMU, PCMA

General

Parameter H30-709S WM-042S CM-600S
Operating temperature 0 °C to +55 °C (32 °F to 131 °F)
Operating humidity 5% – 85%
Material Aluminum (IP65-rated) Aluminum (IP65-rated) 6.5″ woofer with polypropylene cone
Rated power 30 W 20 W 30 W
Power supply PoE or 12–24 VDC
Installation Wall, pole or ceiling mount Wall mount (bracket included) Ceiling mount
Dimensions 11 × 10 × 10″ (246 × 292 × 23 cm) 11 × 6 × 4″ (290 × 150 × 103 mm) 9 × 9 × 5.3″ (203 × 203 × 135 mm)
Net weight 5 lb 3 lb 2 lb

Still stuck? Our support team can help with setup and configuration.

support@linortek.com