User Manual
Netbell SIP Speakers WM-042S · CM-600S · H30-709S
Install, network and configure Netbell VoIP SIP/multicast speakers for live paging and emergency notifications from your phone system.
01Overview
Netbell VoIP SIP/multicast speakers are a cost-effective indoor paging solution with Power over Ethernet (PoE 802.3af) and Voice over IP (VoIP). They are designed for offices, schools and medium-sized warehouses with ceilings over 20 ft, where horn speakers are not required and hallways do not need forward-focused coverage.
The speakers integrate with VoIP phone systems for live paging, emergency notifications and other mass messages, and support multicast and broadcast audio from a single endpoint to many speakers at once.
| Model | Type | Power |
|---|---|---|
| Netbell-WM-042S | Wall-mount speaker | 12/24 VDC or PoE · 20 W |
| Netbell-CM-600S | Ceiling speaker | 12/24 VDC or PoE · 30 W |
| Netbell-H30-709S | Horn speaker | 12/24 VDC or PoE · 30 W |
02What’s in the Box
| Item | Qty |
|---|---|
| SIP speaker | 1 |
| Waterproof cap | 1 |
| Mounting bracket set (WM-042S only) | 1 |
| Installation drawing | 1 |
03Preparation for Installation
For the best audio quality, we recommend a dedicated VLAN for the speakers, using network equipment that supports multicast. Netbell SIP speakers support PoE/PoE+, and a properly configured network makes installation smooth.
Network Requirements
- The speakers and the PC running the SIP Config Tool must be on the same LAN.
- PoE/PoE+ switch ports, with enough switch capacity for the power load of all devices.
- Minimum CAT5 cable, at most 100 m (328 ft) from each device to the switch.
- Port 5060 (UDP/TCP, SIP signaling) open on your router or firewall.
- Router: PIM is required if multicast traffic must pass through multiple routers.
- Switch: should support IGMP snooping to prevent multicast flooding.
Pre-Installation Planning
We strongly recommend configuring all speakers before installing them. It significantly reduces installation time, minimizes errors and simplifies troubleshooting, especially across larger facilities.
- Create a network plan. Document your IP addressing scheme so all devices have compatible settings (subnet mask, gateway, etc.).
- Assign static IP addresses. Configure and document a static IP for every device, to avoid problems caused by changing DHCP addresses.
- Keep a spreadsheet of device numbers and names, IP addresses, installation locations and any special settings.
- Test every speaker while it is easy to reach, before mounting it somewhere hard to access.
- Mount each speaker following the installation drawing supplied with it.
Powering the Speaker
Connect the speaker to your PoE network with a CAT5/5e/6 cable. If PoE is not available, use a 12/24 VDC power adapter (not supplied).
Do not use PoE and a power adapter at the same time.
Once powered, the green LED blinks and the blue LED stays solid: the speaker is ready to be discovered.
04Installing the SIP Config Tool
Download the SIP Config Tool from Support Programming:
- 64-bit installer (recommended): run it and follow the prompts.
- ZIP package: extract it, keep all files together (do not move or delete any), and double-click the
.exe.
If Windows shows “Windows protected your PC”, click More info → Run anyway.
05Configuring the Speaker
Setting the Device IP
- In the SIP Config Tool, click Search Devices.
- When the speaker appears, check its IP address matches your network. The default is
192.168.1.xxx. - If not, select the speaker (it highlights blue) and enter the correct IP Address, Subnet Mask and Gateway under Basic Equipment Parameters at the top.
- Click Save, wait about 10 seconds, and click Search Devices again.
- Double-click the speaker in the list. Your default browser opens its login page.
Logging In
Log in with the default credentials: username admin, password 123456. If the page doesn’t load, check the IP configuration again.
Checking Network Settings
Once logged in, check the Primary and Secondary DNS addresses match your network. To change them, go to the Network page, adjust and save. Then continue to the SIP Settings page.
Entering the SIP Account
On the SIP Settings page, enter the details from your VoIP system administrator:
| Field | Value |
|---|---|
| User Account | Paging account username |
| Password | Account password |
| Display name | Shown on your network |
| Server address | SIP domain or registrar |
| Server port | Usually 5060 |
| Outbound proxy address and port | If required |
| Authentication User | Authorization ID, if required |
Click Save, then Logout and log back in to apply.
After logging back in, the System Overview should show Server Status: Connected and your SIP server address. If not, check your SIP credentials and DNS settings.
Session Audio Settings
Open Work Settings → Intercom:
| Setting | Value |
|---|---|
| Input Channel | Leave at MIC |
| Input Gain (Volume) | Gain for intercom |
| AEC Level | Optional echo/noise cancellation |
| Auto Answer | 0 (paging/intercom starts automatically) |
| Ring Volume | Ring volume for intercom |
| Talk Volume | Set for clear audio (intercom and paging) |
| Codec priority | Enable all three, in this order: G.722 (preferred, if supported), G.711u (most compatible; recommended in the U.S.), G.711a (European systems). |
Forwarding Audio (RTP Unicast, Multicast, Broadcast)
Each speaker can forward audio to one RTP address. On the same page:
- Enable Remote Audio Forwarding.
- Set Protocol Type to
RTP. - Enter the target address (see the table), then click Save.
- Log out and log back in to apply.
| Target | Address |
|---|---|
| Unicast | <IP address>:<port> |
| Multicast | <multicast address>:<port>, multicast range 224.0.0.1 – 239.255.255.254 |
| Broadcast | 255.255.255.255:<port> |
Ports can be 1024–65535.
Receiving Audio (RTP)
Each speaker can receive audio from up to ten RTP addresses. Open Work Settings → Multicast, enter up to 10 addresses, and set Play Volume (1–100).
06Security and Maintenance
Changing the Password
- Open Advanced Settings → Security.
- Enter and confirm the new password, and save.
- Log out to confirm.
Change the default password (123456) on every speaker before installation.
Upgrade, Reset or Reboot
Open Advanced Settings → Maintenance:
- Upgrade: click Choose File, select the firmware, click Upgrade, then Reboot. Check the new version on the Maintenance page.
- Reboot: click Reboot.
Reset restores factory defaults and permanently erases all your settings.
07Specifications
Audio
| Parameter | H30-709S | WM-042S | CM-600S |
|---|---|---|---|
| Codec | G.711u (PCMU) 8 kHz · G.711a (PCMA) 8 kHz · G.722 16 kHz | ||
| Max SPL | 122 dB | 100 dB | 100 dB |
| Frequency response | 350 Hz – 15 kHz | 85 Hz – 20 kHz | 85 Hz – 20 kHz |
| Frequency range | 85 Hz – 2 kHz +10 dB; 400 Hz – 20 kHz +20 dB | ||
| Harmonic distortion | ≤10% @ 1 kHz – 20 kHz | ||
| Signal-to-noise ratio | 109 ±3 dB | 91 ±3 dB | 91 ±3 dB |
| Amplifier | Built-in 30 W | Built-in 20 W | Built-in 30 W |
Network (all models)
| Parameter | Specification |
|---|---|
| Security | Password protection, IP address filtering, digest authentication |
| Network protocols | SIP, HTTP, IPv4, RTP, RTCP, UDP, DNS, ARP |
| Network interface | 10/100 Base-TX, RJ45 |
| VoIP | 1 SIP account, SIP direct IP call, RTP unicast/multicast/broadcast; codecs G.722, PCMU, PCMA |
General
| Parameter | H30-709S | WM-042S | CM-600S |
|---|---|---|---|
| Operating temperature | 0 °C to +55 °C (32 °F to 131 °F) | ||
| Operating humidity | 5% – 85% | ||
| Material | Aluminum (IP65-rated) | Aluminum (IP65-rated) | 6.5″ woofer with polypropylene cone |
| Rated power | 30 W | 20 W | 30 W |
| Power supply | PoE or 12–24 VDC | ||
| Installation | Wall, pole or ceiling mount | Wall mount (bracket included) | Ceiling mount |
| Dimensions | 11 × 10 × 10″ (246 × 292 × 23 cm) | 11 × 6 × 4″ (290 × 150 × 103 mm) | 9 × 9 × 5.3″ (203 × 203 × 135 mm) |
| Net weight | 5 lb | 3 lb | 2 lb |