Owner’s and Operation Manual

iTrixx WFMN Wi-Fi Hour Meter

Connect, wire and configure the iTrixx WFMN-DI and WFMN-ADI Wi-Fi hour meters, and set up triggers, email, MQTT and data collection.

Updated November 3, 2026 12 min read Download PDF
Overview

01Overview

Figure 1iTrixx WFMN

This manual covers the iTrixx WFMN-DI and iTrixx WFMN-ADI Wi-Fi hour meters. Both have two hour meters, two digital inputs and two relays; the ADI model adds two analog inputs. You configure them with text commands over Telnet.

Model Digital inputs Analog inputs Cables
WFMN-DI 2 – 1 (power and digital inputs)
WFMN-ADI 2 2 3 (analog inputs, relays, power and digital inputs)
Easier with WFCC

The free WiFi Hour Meter Control Center (WFCC) program for Windows connects your iTrixx to Wi-Fi, sets triggers, relays and MQTT without Telnet, collects the run hours automatically and emails a daily report.

02Connecting to Your Wi-Fi Network

After powering on the iTrixx, connect it to your Wi-Fi network:

  1. Press and hold the DFLT button until the blue LED flashes. The device is now in provisioning mode for 2 minutes.
  2. On a Wi-Fi-enabled PC or mobile device, connect to the network named WiFiHM_xx:xx:xx. The x’s are the last 6 characters of the device’s MAC address; write them down, as you’ll need them later.
  3. Enter the password wifihmpsk. If you get a “no internet connection” message, ignore it.
  4. In your browser, go to http://wifihm-config.com.
  5. Enter your Wi-Fi network name under Network Name and its password under Pass phrase.
  6. Click Connect. The blue LED stops blinking and stays on: the iTrixx is connected.
Figure 2Connecting to the WiFiHM network
Figure 3Entering your Wi-Fi details
Tip

You can also connect the iTrixx to Wi-Fi from WFCC’s Wi-Fi setup page, without a browser, and set up several meters in a row. See Connect Controllers to Wi-Fi in the WFCC User Guide.

03Getting to Know the Hardware

Wire Chart

The WFMN-DI has 1 cable and the WFMN-ADI has 3. From top to bottom they are cables 1, 2 and 3.

Figure 4Cables

Cable 1: Analog inputs (WFMN-ADI only)

Wire Function Note
Green AIN 1 Analog 1
Brown Return
Red 5 V For a 12 V sensor, use a 12 V power supply
White AIN 2 Analog 2
Blue Return
Black 5 V For a 12 V sensor, use a 12 V power supply

Cable 2: Relay outputs (WFMN-ADI only)

Wire Function
Brown Relay 1 NC
Green Relay 1 C
Red Relay 1 NO
Blue Relay 2 NC
White Relay 2 C
Black Relay 2 NO

Cable 3: Digital inputs and power

Wire Function Note
Red 12–48 VDC Power input
Black Ground
Green DIN 1 A Input 1, 5–24 VDC
White DIN 1 C
Brown DIN 2 A Input 2, 5–24 VDC
Blue DIN 2 C
Important

For a digital input voltage above 12 VDC, you must use a 2.2 kΩ resistor.

Board Layout Reference

The terminal connectors come pre-wired for power, digital inputs and analog inputs.

Figure 5iTrixx WFMN boards

04Wiring the iTrixx

Before powering on the iTrixx, install it on your equipment. This involves tapping circuits on the equipment you want to monitor.

Warning

To prevent electric shock, injury, death or equipment damage, switch off power to the equipment at the circuit breaker. On a vehicle, disconnect the battery. Installation should be done by a qualified technician or electrician.

Digital Inputs

The iTrixx has 2 digital inputs (5–24 VDC) for triggering notifications and alerts and for monitoring run time. Wire a circuit that switches on and off with your equipment to detect whether the machine is running.

Each input has two modes, selected by its switch on the board (see Board Layout Reference):

Mode How it works Default state Switch
ISOLATED You drive the opto-isolator directly with an external voltage through an internal 1 kΩ resistor. The voltage can be 5–24 VDC, supplying a minimum of 2 mA and a maximum of 30 mA. There is no other internal connection to this voltage. OFF Right (toward the center of the board)
PULL-UP Connects a 1 kΩ resistor to an internal voltage, so you can use a simple switch (such as a magnetic door switch) across terminals 1 and 2. ON Left (toward the edge of the board)

Wiring your equipment

  1. Find a 5–24 VDC circuit on your equipment that switches on and off with it.
  2. Wire it to DIN 1 or DIN 2. For a circuit above 12 VDC, put a 2.2 kΩ resistor (0.5 W; provided on request) between the circuit and the iTrixx. The iTrixx only detects the voltage; it draws no power and doesn’t interfere with the circuit.
  3. Power on your equipment (or reconnect the vehicle battery) and configure the device; see Setting Triggers.
Important

Do not exceed 24 VDC on a digital input.

Analog Inputs (WFMN-ADI)

The ADI model has 2 analog inputs (5 V, 4–20 mA) for sensors such as tank-level or pressure sensors; their readings can trigger notifications. Each analog input has 3 wires; see Cable 1.

Relay Outputs

The iTrixx has two relay outputs limited to a 5 V signal. Each has three positions, NO (Normally Open), C (Common) and NC (Normally Closed), and its own switch on the board: right for a dry contact, left to drive a 5 VDC signal. See Board Layout Reference.

Powering the iTrixx

Use the supplied 12 VDC power supply, or tap a 12–48 VDC circuit on your equipment. Once powered, the iTrixx is ready to connect to your network.

Example: Wiring to a Forklift

Figure 6iTrixx WFMN forklift wiring diagram

05Connecting to the iTrixx

To configure the iTrixx you need its IP address and a Telnet client on your computer.

Finding the IP Address

  • Hour Collector app (easiest): the iTrixx appears when it connects to your network. If it is already connected, press RESET and it appears after rebooting.
  • WFCC: on the Controllers page, click Scan network. A meter set up through WFCC’s Wi-Fi setup page is added with its address automatically.
  • Your router: look in the list of connected devices for WiFiHM_xxxxxx, where the x’s are the last 6 characters of the MAC address.

Hour Collector App

Download Hour Collector free from Support Programming; it needs Java. It finds your iTrixx automatically, but a Wi-Fi meter appears only after Hour Collector receives data from it. Hour Collector updates every two minutes.

On first launch it creates a CSV_FILE folder on your desktop with a .csv log you can open in Excel. The log only updates while Hour Collector is running and the .csv file is closed.

Hour Collector shows: IP address, meter name, date/time, meter 1 and meter 2, inputs, relays, sensors, port number (if ported) and MAC address. Click DATA SELECTION to choose what is displayed. Write All Data writes everything to the .csv file whether displayed or not; uncheck it to write only the selected data.

Figure 7Hour Collector

Connecting with Telnet

Turn on the Windows Telnet client

  1. Open Control Panel › Programs.
  2. Under Programs and Features, click Turn Windows features on or off.
  3. Check Telnet Client and click OK.

Connect to the iTrixx

  1. Open Command Prompt.
  2. Enter telnet <IP address> 30316, for example telnet 192.168.1.50 30316.
  3. Enter the password: by default, the last 6 characters of the MAC address without colons, printed on the enclosure (e.g. cd56ef).
  4. The available commands are listed in the window.
Figure 8Telnet session

06WiFi Hour Meter Control Center (WFCC)

WFCC is a free Windows 10/11 program for iTrixx WFMN meters with firmware 0.62 or later. It runs on one PC on the same network as your meters and does in a few clicks what otherwise takes Telnet commands:

Page What it does
Wi-Fi setup Connects new or reset meters to your Wi-Fi (2.4 GHz WPA2), with no browser needed.
Controllers Adds meters by network scan, by IP address or from a CSV file, and names each hour meter.
Dashboard Shows how long each meter ran yesterday, the day before, today and over the last 7 days. WFCC reads every meter once an hour.
Program Sets triggers (what starts each meter), switches relays, sets pulse mode and MQTT, on one or many meters at once.
History & CSV Saves every reading to readings.csv and exports hours per day for Excel.
Daily email Emails the readings and hours worked every morning from a Gmail account, compared with the day before.
Figure 9The WFCC Dashboard

Getting Started with WFCC

  1. Download WFCC 1.4.0 (ZIP), extract it, and run WiFi Hour Meter Control Center Setup 1.4.0.exe. If Windows shows Windows protected your PC, click More info › Run anyway.
  2. Connect new meters on the Wi-Fi setup page, or add meters already on your network on the Controllers page.
  3. Name the hour meters in Settings, and set what starts each meter on Program › Triggers.
  4. Set up the Daily email, and in Settings tick Start with Windows, so WFCC keeps collecting.

WFCC logs in to each meter with the same password as Telnet (by default the last 6 characters of the MAC address, lowercase, without colons). For every step, see the WFCC User Guide.

One program at a time

An iTrixx accepts one programming connection at a time. Close Hour Collector or any Telnet window connected to the same meter before you program it from WFCC.

07Configuring the iTrixx

You configure the iTrixx by typing commands in the Telnet window. This chapter covers the basics; for every command, see Appendices. Most of these settings can also be made without Telnet in WFCC.

Important

Enter save after making changes, or they will be lost when the iTrixx reboots.

Naming the Server

Enter server=<name> to make the iTrixx easier to identify on your network.

Time and Date

Command What it does Example
timezone=x Time zone offset from GMT (default GMT). timezone=-5 (EST)
time Shows the current time in ISO 8601 format, yyyymmddThhmmss plus offset. 20200422T133000-0400 = April 22, 2020, 1:30 PM GMT-4
ntphost=<host> NTP server (default time.nist.gov). ntphost=time.nist.gov
ntpperiod=x Minutes between time updates (default 11). ntpperiod=11

Email Notifications

The iTrixx supports SSL email. You need your provider’s SMTP server, a “send from” address and its password, and a “send to” address.

Command What it sets Example
emailsmtphost=<server> SMTP server of the “send from” account, e.g. smtp.gmail.com (Gmail), smtp.mail.yahoo.com (Yahoo), smtp.mail.me.com (iCloud). emailsmtphost=smtp.gmail.com
emaillogin=<address> Username of the “send from” account. emaillogin=myemail@gmail.com
emailpassword=<password> Password of the “send from” account. emailpassword=mypassword
emailto=<address> The “send to” address. emailto=destination@yahoo.com
emailperiod=x Send a report every x minutes. emailperiod=30

08Setting Triggers

Triggers activate the iTrixx’s features. Each trigger has three parts separated by commas:

trigger=<source>,<value>,<target>

  • Source: what activates the trigger.
  • Value: the condition the source must meet.
  • Target: what to do.

Sources

Source Names Notes
Relays relay.1, relay.2
Digital inputs din.1, din.2, dinfreq.1, dinfreq.2 dinfreq = input frequency
Analog inputs ain.1, ain.2
Hour meters hm.1, hm.2
Temperature tsensor Board thermistor, in °C; reads higher than ambient.
Time time To turn on a relay, the relay needs a duration (relaypulse; see Technical Reference).
Duration duration.1 – duration.6 Time since the source became active; resets to zero when it becomes inactive.
Accelerometer shock Value 0.000–8.000. 1 = no movement; higher values need more vibration or impact.

Values

Relays and digital inputs use high (on) or low (off). Other sources use the comparisons below. Analog inputs, digital frequency, temperature and accelerometer values need two numbers separated by a colon: the first activates the trigger and the second resets it so it can activate again.

Value Meaning Examples
gt Greater than hm.2,gt.5 · ain.1,gt.5.5:3.2
ge Greater than or equal to hm.1,ge.3 · shock,ge.4.1:2.5
lt Less than hm.2,lt.4 · tsensor,lt.34:40
le Less than or equal to hm.1,le.10 · ain.2,le.4.3:5.8
in In the range hm.2,in.5:10 · tsensor,in.35:40
out Outside the range hm.1,out.10:20 · ain.1,out.1:1.3
eq * Equal to hm.2,eq.20
neq * Not equal to hm.1,neq.35
every * Every x (interval) hm.2,every.50

* Hour meter triggers only.

Time Triggers

A time value has a repeat period (hh.mm) and/or a start date/time, which must always be preceded by a colon:

To do this Command
Activate relay 1 every 30 minutes trigger=time,00.30,relay.1
Activate relay 2 every hour trigger=time,01.00,relay.2
Send a report every 1.5 hours from April 8, 2020, 6:00 PM trigger=time,01.30:20200408T1800,report
Activate relay 1 on July 4, 2020, 12:00 AM trigger=time,:20200704T0000,relay.1

Targets

relay.1, relay.2, hm.1, hm.2, duration.1 – duration.6, resethours.1, resethours.2 or report. The report target forces an update to the Hour Collector app and sends an email if email is set up.

Example Triggers

Command What it does
trigger=relay.2,high,hm.2 When relay 2 is on, run hour meter 2.
trigger=din.1,high,hm.1 When digital input 1 is on, run hour meter 1.
trigger=ain.2,lt.3.5:4.1,relay.2 When analog input 2 is below 3.5 (resets at 4.1), turn on relay 2.
trigger=hm.1,eq.100,report When hour meter 1 reaches 100 hours, send a report.
trigger=tsensor,ge.40:35,relay.1 When the temperature is 40 °C or more (resets at 35 °C), turn on relay 1.
trigger=shock,gt.5:1,report When the accelerometer reads above 5 (resets at 1), send a report.
trigger=din.2,high,duration.1 When digital input 2 is on, start duration 1.
trigger=duration.1,ge.60,report When duration 1 reaches 60 seconds, send a report.
trigger=duration.1,ge.120,resethours.1 When duration 1 reaches 2 minutes, reset hour meter 1 to zero.

Viewing and Deleting Triggers

  • triggersdump lists all triggers, numbered.
  • triggerdelete=x deletes trigger number x from that list.

09MQTT and XML

MQTT

The iTrixx can publish its JSON payload to an MQTT broker, under the topic lt1000/<MAC address>/tele (e.g. lt1000/AB:CD:EF:12:34:56/tele).

Command What it sets Example
mqtthost=<address> Broker address (48 characters max, from v0.62.9) mqtthost=172.16.1.41
mqttport=<port> Broker port mqttport=1883
mqttuser=<client ID> Client ID mqttuser=clientname
mqttpassword=<password> Broker password mqttpassword=brokerpw
mqttssl=0|1 Disable (0) or use (1) SSL mqttssl=1
mqttperiod=<seconds> Report frequency mqttperiod=60

XML Payload

From software version 0.62.8 (released April 10, 2025), hour meter readings with the G value (impact) are available at http://<WFMN IP>/hours.xml for upload to your own software.

10Factory Reset

Using the Buttons

  1. Press the RESET button. The blue, green and red LEDs come on one by one, and the red LED stays solid (Bootload state).
  2. While the red LED stays solid, press and hold the DFLT button for about 10–15 seconds, until the blue, green and red LEDs come back on.

Using Telnet

Enter factory_reset.

11Appendices

These reference documents are PDFs. They open in a new tab.

Still stuck? Our support team can help with setup and configuration.

support@linortek.com