Installation and Operation Manual
iTrixx-LHM LoRa Hour Meter System
Install, configure and operate the iTrixx-LHM LoRa server and up to 100 wireless client devices for long-range monitoring.
01Overview
The iTrixx-LHM is a long-range wireless monitoring and control system for industrial, commercial and infrastructure sites. It has one central server and up to 100 remote client devices, which communicate over LoRa radio, so you can collect data and control equipment over long distances where wired or Wi-Fi connections are impractical.
Key Capabilities
- Monitor remote equipment status and meter readings
- Collect digital input signals (alarms, switches, sensors)
- Configure automated triggers and presets
- Store and export operational data
- Integrate with external systems via database or JSON API
All management is done through a secure web interface.
Communication Range
LoRa (Long Range) radio is optimized for low-power, long-distance communication. The iTrixx-LHM uses the 915 MHz ISM band, license-free throughout North America. Range depends on the environment, from several hundred meters in dense industrial sites to several miles in open areas.
| Best performance | Reduced performance |
|---|---|
| Clear line of sight between devices | Thick walls |
| No metal, concrete or earth in the way | Steel structures |
| Antennas mounted high | Below-grade placement |
| Outdoor or open areas | Heavy machinery interference |
System Architecture
- One server is the main controller and data hub.
- Multiple clients communicate wirelessly with the server.
- All data is stored on the server, with optional export to a database.
- You use the system through a web browser.
This gives centralized management, less wiring, and a system that is easy to scale and expand.
02System Components
| Component | Description |
|---|---|
| Server (iTrixx-LHM-S) | Communications gateway and management server, with web configuration interface and PoE-powered Ethernet. |
| Client (iTrixx-LHM-C) | Radio module with digital inputs and meter interfaces in an indoor/outdoor enclosure. C-AC: 100–240 VAC, 50/60 Hz. C-DC: 12–24 VDC, typically 10 mA at 12 V. |
What’s in the Box
| Server: LHM-S | Client: LHM-C-AC | Client: LHM-C-DC |
|---|---|---|
| Server | Client | Client |
| 915 MHz antenna | 915 MHz antenna | 915 MHz antenna |
| RJ45 cable | Power cable | 12 VDC power supply |
| Digital input connector cable (2) | WAGO connector (2) |
03Specifications
| Specification | Server (LHM-S) | Client (LHM-C) |
|---|---|---|
| Wireless technology | LoRa | |
| Frequency | 915 MHz ISM band (license-free in North America) | |
| Devices | Up to 100 clients (addresses 00–99) | Address set with rotary switches (00–99) |
| Range | Up to 3 km urban / 5+ km rural (line of sight); indoors 500 m to 1+ km depending on structure | |
| Encryption | AES-128 | |
| Antenna | Replaceable 915 MHz antenna | |
| Power | PoE+ (IEEE 802.3at) via Ethernet | AC: 110–120 VAC plug-in or 100–240 VAC hardwired, 50/60 Hz DC: 12–24 VDC from the supplied power adapter or the equipment’s own DC circuit, typically 10 mA at 12 V |
| Network | 10/100/1000 Base-T Ethernet; DHCP or static IP; hostname linortek-lhm |
– |
| Web interface | HTTPS web server (port 8443); browser-based configuration and monitoring | – |
| Data | Export to PostgreSQL or MySQL; JSON API endpoint; automatic CSV logging | – |
| Users and security | Multi-user with role-based access; HTTPS; password protection | AES-128 encrypted wireless |
| Inputs | – | 2 dry-contact inputs for switch or relay closures |
| Indicator | – | Optional maintenance LED |
| Enclosure | Indoor | Weatherproof, NEMA-rated |
| Operating temperature | Standard indoor environment | −20 °C to +70 °C (−4 °F to +158 °F) |
04Installation
Power Requirements
- Server: PoE+ (802.3at). If PoE+ isn’t available, use a PoE injector (not included).
- Client C-AC: plug-in 110–120 VAC, or hardwired 100–240 VAC, 50/60 Hz.
- Client C-DC: 12–24 VDC, 10 mA at 12 V. Use the supplied 12 VDC power adapter, or connect to a 12–24 VDC circuit on your equipment.
Server Installation
- Install indoors, in a central location, as high as reasonably possible.
- Keep the antenna away from metal surfaces.
- Keep a line of sight to the clients where possible.
| Acceptable (reduced range) | Avoid where possible |
|---|---|
| Light walls (drywall, wood) | Thick concrete |
| Some furniture | Metal panels and steel structures |
| Glass | Underground or below-grade placement |
| Large machinery between server and clients |
Connect the server
- Screw the 915 MHz antenna onto the gold connector.
- Connect the server’s network jack to a PoE+ (802.3at) switch port or PoE+ injector with the supplied RJ45 cable. This cable powers the server.
Server status LEDs
| LED | Meaning |
|---|---|
| Red solid | The server has power. |
| Green blinking twice per second | Normal operation. |
| Green blinking rapidly | Boot mode: the server is starting up. |
Client Installation
Configure the system and confirm the server and client communicate before installing.
The digital inputs accept dry-contact closures only (relay contacts or switches). Do not apply external voltage to them. See Appendix: Wiring the Client.
- Mount near the monitored equipment. Mounting hardware is not included; use hardware suited to the surface.
- Place the antenna away from metal and keep a line of sight to the server (see Server Installation).
- Clients are suitable for indoor and outdoor use.
Client C-AC Wiring
Connect the AC client with the supplied power cable (110–120 VAC) or hardwire it to a 100–240 VAC supply.
- Route the power cable or supply wires through the cable gland labeled Power, and screw the cap tight to secure the cable and seal the enclosure.
- Remove the four screws holding the internal mounting plate to reach the power supply terminals.
- Connect the AC wires to L (live), N (neutral) and G (ground), and tighten the terminal screws.
- Refit the mounting plate with the four screws.
- Connect your equipment to the digital inputs with the supplied connector cable.
- Check all connections are secure before powering on.
| Supplied cable wire | Connection |
|---|---|
| Black | Live (L) |
| White | Neutral (N) |
| Green | Ground (G) |
Client C-DC Wiring
The DC client comes with a 6-conductor cable already fitted through the cable gland.
| Wire | Connection |
|---|---|
| Red | 12–24 VDC |
| Black | Ground (GND) |
| Green | DIN1 A |
| White | DIN1 C |
| Brown | DIN2 A |
| Blue | DIN2 C |
Power the DC client: choose one
| Option | How to connect |
|---|---|
| A. Supplied 12 VDC power adapter | Join the client’s red wire to the adapter’s + wire and the black wire to its − wire with the supplied WAGO connectors. Plug the adapter into an outlet. |
| B. Your equipment’s 12–24 VDC circuit | Connect the red wire to +12–24 VDC and the black wire to ground (−) on the equipment. No adapter needed. |
Important: make sure the supply is between 12 and 24 VDC and the polarity is correct before you power it on. Switch off the equipment’s power while you wire it.
05Client Configuration
Setting the Client Address
- Power off the client.
- Open the enclosure with a Phillips screwdriver.
- Set the two-digit ID on the rotary switches: S2 = first digit, S1 = second digit. S4 sets the AES key.
- Close the enclosure and power on.
Example: S2 = 0 and S1 = 1 gives device ID 01.
Each client must have a unique ID; duplicates cause communication conflicts. Keep a list of IDs and label each enclosure.
06Server Configuration
Finding the Server IP Address
The server’s hostname is linortek-lhm. Find its IP address in your router’s DHCP client list, with an IP scanner, or from Command Prompt or PowerShell:
This works if your PC is on the same subnet as the server, or if your network allows traffic between subnets.
Web Access and First Login
- Open a browser and enter the server’s IP address.
- Accept the security warning (the server uses a self-signed certificate).
- On first access, create an administrator account. The password needs at least 8 characters, with an uppercase letter, a lowercase letter, a number and a special character.
- Log in with your new credentials.
Main Page
The Main page shows the server IP address, network port, software version and number of pending commands. Once clients are added, they are listed below, where you can modify their settings, send commands or delete them.
The JSON button at the top right opens raw data for all registered clients (available once devices are added).
Adding Client Devices
- On the Main page, click Add New Device.
- Enter the 2-digit Device ID (set on the client’s rotary switches), a nickname, and the data options you want.
- Click Add Device. The server starts communicating with it automatically.
Data Page
The Data page shows real-time readings and the latest status of each client (green online, red offline). The table refreshes automatically; click Clear Data to empty it until new data arrives.
Configuring a Client and Sending Commands
Click the Command button for a device:
| Control | What it does |
|---|---|
| Meter 1/2 control | Start and stop a meter manually. |
| HM1/HM2 trigger mode | How each meter is activated. If Ext. Power is selected and no battery is connected to the client, the memory may become corrupted. |
| Ext Power Deep Sleep | Whether the client sleeps or stays active when external power is off. Only available with an external battery connected. |
| Meter 1/2 presets | Enable Preset Meter and enter hours including hundredths, without a decimal point; the last two digits are the decimals. E.g. 3600 = 36.00 hours. |
| INIT | Resets the device. |
| Broadcast to all devices | Sends the command to every connected client at once. |
Select the options and click Send Command(s).
User Management
On the Users page:
- Add: click Add User, enter a username and password (same rules as above), confirm the password, check Admin if needed, and click Add User.
- Modify: click Modify, edit the name, password or role, and click Modify User.
- Delete: click Delete and confirm.
| Role | Access |
|---|---|
| Admin | Full system access. An admin cannot delete or demote themselves. |
| User | Main, Data, Users (own password only) and JSON. Cannot add or delete devices. |
Network Settings
| Setting | How |
|---|---|
| DHCP (automatic IP) | Check Use DHCP and click Update Network. |
| Static IP | Uncheck Use DHCP, enter the IP address, network mask and default gateway, and click Update Network. |
| NTP server | Enter the time server (default time.nist.gov) and click Update NTP. |
| Time zone | Select your time zone and click Update Timezone. |
| HTTPS certificates | Certificate Mode: default or custom. Upload Certificates: .crt and .key files from your IT team. Download Cert: the current certificate. Force Renew: generate a new one. Click Update Cert Settings. |
After changing the IP address, reconnect using the new address.
Communications: Radio Polling and Database Export
Radio polling
Sets how often the server talks to the clients. Choose the polling mode and interval, enable automatic polling for continuous monitoring, and click Save. We recommend the default values unless you need to optimize.
Database auto export
- Enable Database Auto Export.
- Select PostgreSQL or MySQL.
- Enter the host IP, port, database name, username and password.
- Click Save.
Software Updates
- Open Software Update and click Choose File.
- Select the
.encupdate file and click Apply Update. - Wait for the system to restart.
Do not power off the server during an update.
Audit Log
Records system activity and user actions for security and troubleshooting: logins and logouts, password changes, user account changes, devices added or removed, configuration changes, software updates and commands sent.
Help Page
| Section | Contents |
|---|---|
| Quick Tips | Reminders for setup, operation and maintenance. |
| User Manual | Click Download PDF Manual for the latest version. |
| Certificate Update Script | Installs the security certificate automatically on Windows; run it if your network administrator requires it. |
| Support | Documentation links and technical support contacts. |
07Resetting the Server to Factory Settings
- Check power. With the server on PoE, check the red and green LEDs on the right side of the enclosure are both solid.
- Open the enclosure. Remove the four Phillips screws on the top lid and lift it carefully.
- Find the buttons. On the top board there are three push buttons; you’ll use Button 1 (top) and Button 2 (middle).
- Start the reset. Press and hold Button 1 for about 10 seconds, until the green LED blinks twice per second, then release it.
- Confirm. Press Button 2 once (don’t hold it). The green LED blinks rapidly for about 5 seconds, then twice per second for another 5 seconds, then stays solid.
- Finish. When the green LED is solid, the reset is complete. Refit the lid with the four screws.
08Troubleshooting
| Problem | Possible cause | Solution |
|---|---|---|
| No data | Duplicate ID | Check the client’s rotary switches. |
| Client offline | No power, weak signal, wrong AES key or wrong ID | Make sure the client is powered, reposition the antennas, check the rotary switches, and check the AES key settings on the server. |
| Cannot log in | Wrong password | Have an admin reset it, or reset to factory settings. |
| No network connection | IP address conflict | Check Network Settings. |
Maintenance
- Keep the server firmware up to date.
- Keep your client ID list up to date.
- Inspect the server’s built-in fan and clean it periodically with a vacuum.
- Back up the database regularly.
AAppendix: Wiring the Client
Still stuck? Our support team can help with setup and configuration.