title: "iTrixx-LHM Server and Client Installation and Operation Manual"
description: "## Overview The **iTrixx-LHM** system is a long-range wireless monitoring and control solution designed for industrial, commercial, and infrastructure applications. It consists of one central server and up to 100 remote client devices. The system enables reliable data collection and…"
url: "https://resources.linortek.com/docs/itrixx-lhm-server-and-client-installation-and-operation-manual/"
updated: "2026-05-13"
category: iTrixx
---

# iTrixx-LHM Server and Client Installation and Operation Manual

## Overview

The **iTrixx-LHM** system is a long-range wireless monitoring and control solution designed for industrial, commercial, and infrastructure applications. It consists of one central server and up to 100 remote client devices.

The system enables reliable data collection and remote control over long distances using LoRa radio communications, even in environments where traditional wired or Wi-Fi connections are impractical.

iTrixx-LHM is intended for facilities that require continuous monitoring and centralized data access with minimal wiring and maintenance.

### Key Capabilities

The iTrixx-LHM system allows users to:

- Monitor remote equipment status and meter readings
- Collect digital input signals (alarms, switches, sensors)
- Configure automated triggers and presets
- Store and export operational data
- Integrate with external systems via database or JSON API

All system management is performed through a secure web-based interface.

### Communication Range and Environment

The iTrixx-LHM system uses LoRa (Long Range) radio technology, which is optimized for low-power, long-distance communication. This operates at 915MHz utilizing the ISM band for license-free usage throughout North America.

Actual communication range depends on environmental conditions.

| **Best Performance Conditions** | **Reduced Performance Conditions** |
| --- | --- |
| Clear line-of-sight between devices | Thick walls |
| No metal, concrete, or earthen obstructions | Steel structures |
| Elevated antenna placement | Below grade placement |
| Outdoor or open-area deployment | Heavy machinery interference |

Typical ranges may vary from several hundred meters in dense industrial environments to several miles in open areas.

### System Architecture

**The iTrixx-LHM system follows a centralized architecture:**

- One server acts as the main controller and data hub
- Multiple clients communicate wirelessly with the server
- All data is stored locally on the server with the option to export to a database
- Users access the system through a web browser

**This architecture provides:**

- Centralized management
- Reduced wiring requirements
- Scalable deployment
- Easy expansion

## System Components

### Server

- Communications gateway and management server
- Web-based configuration interface
- Ethernet connectivity (PoE powered)

### Client Devices

- Radio communication modules
- Digital inputs and meter interfaces
- 100-240VAC, 50/60Hz power input for **iTrixx-LHM-C-AC**
- 12-24VDC, typical current 10mA@12V for **iTrixx-LHM-C-DC**
- **Indoor/outdoor enclosure**

## What’s in the Box

| **Server Package** | **Client Package** |  |
| --- | --- | --- |
| iTrixx-LHM-S | iTrixx-LHM-C-AC | iTrixx-LHM-C-DC |
| Antenna 915 MHz | Antenna 915 MHz | Antenna 915 MHz |
| RJ45 Cable | Power Cable | 12 VDC Power Supply |
|   | Digital Input Connector Cable (2) |   |
|   |   |   |

## Specifications

| **Specification** | **iTrixx-LHM-S (Server)** | **iTrixx-LHM-C (Client)** |
| --- | --- | --- |
| **Wireless Technology** | LoRa |  |
| **Frequency** | 915 MHz | 915 MHz ISM band (license-free in North America) |
| **Supported Devices** | Up to 100 clients (addresses 00–99) | Address selectable via rotary switches (00–99) |
| **Range** | Up to 3 km urban / 5+ km rural (line-of-sight) |  |
| **Indoor Range** | 500 m to 1+ km depending on structure |  |
| **Encryption** | AES-128 secure communication |  |
| **Antenna** | Replaceable 915 MHz antenna |  |
| **Power Input** | PoE (IEEE 802.3at) via Ethernet | **AC model**: 110–120 VAC plug-in or 100–240 VAC hardwired, 50/60Hz **DC model**: 12/24 VDC hardwired, typical current: 10mA@12V |
| **Network Interface** | 10/100/1000 Base-T Ethernet | — |
| **IP Configuration** | DHCP or Static IP | — |
| **Hostname** | Linortek-lhm | — |
| **Web Interface** | HTTPS web server (port 8443) | — |
| **Dashboard** | Browser-based configuration & monitoring | — |
| **Database Export** | PostgreSQL or MySQL | — |
| **API Access** | JSON endpoint for integrations | — |
| **Data Logging** | Automatic CSV generation | — |
| **User Management** | Multi-user with role-based access | — |
| **Security** | HTTPS encryption, password protection | AES-128 encrypted wireless |
| **Inputs** | — | 2 × dry contact inputs for monitoring switch or relay closure signals |
| **Indicator** | — | Optional maintenance LED |
| **Enclosure** | Indoor server enclosure | Weatherproof NEMA-rated |
| **Operating Temperature** | Standard indoor environment | −20°C to +70°C (−4°F to +158°F) |

## **Power Requirements**

**Server Power**

- Powered via **Power-over-Ethernet (PoE) –**requires PoE+ (802.3at)
- If PoE is unavailable, use a PoE injector (not included)

**Client Power**

- **iTrixx-LHM-C-AC:** Plug-in 110-120VAC or hardwired 100-240 VAC 50/60Hz
- **iTrixx-LHM-C-DC**: Hardwired 12-24VDC 10mA@12V

## Installation Guidelines

### Server Installation

- Install indoors in a central location
- Mount as high as reasonably possible
- Keep antenna away from metal surfaces
- Maintain line-of-sight where possible
  - Acceptable (works but reduced range):
    - Light walls (drywall, wood)
    - Some furniture
    - Glass

  - Avoid when possible:
    - Thick concrete
    - Metal panels
    - Steel structures
    - Underground or below-grade placement

    - Large machinery between server and client(s)

### Client Installation Important Notes

- Before installing the system, complete the configuration and confirm that communication between the server and client is functioning properly
- The Digital inputs are designed for **dry contact closure signals only** (such as relay contacts or switches). Do **not apply external voltage** to these inputs
  - Refer to **Appendix 1**for Digital Input Wiring Schematic
- Mount near monitored equipment
  - **Note:** Mounting hardware is not provided with the device. Install the enclosure using hardware appropriate for the mounting surface.
- Place antenna away from metal
- Maintain line-of-sight to server (see 5.1 Server installation for more details)
- Suitable for indoor and outdoor use

### iTrixx-LHM-C-AC Model Installation

The **AC-powered** client can be connected using either **the****provided power cable (110–120 VAC)** or **hardwired to a 100–240 VAC supply**.

**Wiring Procedure**

- Route the power cable or supply wires through the cable gland labeled “Power” on the enclosure.
- Tighten the gland by screwing the cap to secure the cable and maintain enclosure sealing.
- To access the power supply terminals, remove the four screws securing the internal mounting plate. This allows easier access to the power supply wiring terminals.
- Connect the AC input wires to the power supply terminals:
  - L (Live)
  - N (Neutral)

  - G (Ground)

**Provided Power Cable Wire Colors**

| **Wire Color** | **Connection** |
| --- | --- |
| Black | Live (L) |
| White | Neutral (N) |
| Green | Ground (G) |

- Secure each wire by tightening the terminal screws.
- Reinstall the mounting plate using the four screws to secure the hardware inside the enclosure.
- Connect your equipment to the digital inputs using the provided Digital Input connector cable.
- Ensure all wiring connections are secure before powering the device.

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image.png)

### iTrixx-LHM-C-DC Model Installation

The DC-powered client is supplied with a **6-conductor cable pre-installed through the enclosure cable gland****.**

**Power Connections**

| **Wire Color** | **Connection** |
| --- | --- |
| Red | 12-24 VDC |
| Black | Ground (GND) |

**Digital Input Connections**

| **Wire Color** | **Connection** |
| --- | --- |
| Green | DIN1 A |
| White | DIN1 C |
| Brown | DIN2 A |
| Blue | DIN2 C |

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-1.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-1.png)

## Client Configuration

### Configure its address

**Steps:**

- Power off the device
- Open enclosure using Phillips screwdriver
- Locate rotary switches:
  - **S2** = First digit
  - **S1** = Second digit

  - **S4** = AES Key
- Set the desired two-digit ID
- Close enclosure
- Power on device

**Example:** S2=0, S1=1, The device ID is 01

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-2.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-2.png)

### Important Notes

- Each client must have a **unique ID**
- Duplicate IDs will cause communication conflicts
- Maintain an ID list
- Label each device enclosure

## Server Configuration

### Finding the Server IP Address

The server hostname is `linortek-lhm`

You can locate the IP address by:

- Router’s DHCP client list
- IP scanner
- Command Prompt/Powershell

Enter the following for **Command Prompt** or **Powershell**:

**ping`-4 linortek-lhm`**

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-3.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-3.png)

**Note:**This command will work if your PC is on the same subnet as the device, or if the network allows communication between subnets.

### Web Access

- Open browser
- Enter server IP address
- Accept security warning (self-signed certificate)
- Proceed to login page

### First-Time Login

On first access, create an administrator account.

Password requirements:

- Minimum 8 characters
- One uppercase letter
- One lowercase letter
- One number
- One special character

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-4.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-4.png)

After setup, log in using created credentials.

### Main Page Overview

After logging in, the **Main Page** displays key system information, including:

- Server IP address
- Network port
- Current software version
- Number of pending commands

Once devices (clients) have been added, the system displays a list of connected clients below this information. From this list, you can:

- Modify device settings
- Send commands (refer to [Configure the Client and Send Commands](#_Configure_the_Client))
- Delete devices as needed

A **JSON** button is located in the upper-right corner of the page. Selecting this button opens the JSON data page, which provides raw device data for all registered clients.

JSON data becomes available after devices have been added to the system.

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-5.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-5.png)

### Adding Client Devices

On the Main Page:

- Click **Add New Device**
- Enter:
  - 2-digit Device ID (set on Client using rotary switches)
  - Nickname

  - Desired data options
- Click **Add Device**

The server will begin communicating automatically.

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-6.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-6.png)

### Data Page – View and Manage Data

Navigate to **Data** page

Features:

- Real-time readings
- Latest status per client (green – online; red – offline)
- Manual refresh
- Client commands

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-7.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-7.png)

#### *Refresh Device Data*

The table refreshes **automatically**. Click **Clear Data** to clear the table until new data comes in

#### *Configure the Client and Send Commands*

Click the **Command**button associated with that device.

**Available controls:**

- **Meter 1/2 control** – Start and Stop the meter manually from UI
- **HM1/HM2 Trigger modes** – Select one of the available options to define how the meters are activated. If **Ext. Power** is selected while no battery is connected to the client device, the memory may become corrupted.
- **Ext Power Deep Sleep** – Select whether the device enters sleep mode or remains active when external power is not applied. This option is available only when **an external battery** is connected.
- **Meter1/2 Presets** – Enable **Preset Meter** and enter the desired value in hours, including hundredths. Do not use a decimal point. The last two digits will automatically be interpreted as the decimal portion. **Example**: Enter **3600** to set the meter to **36.00** hours
- **INIT**– Reset the device by enabling this option
- **Broadcast to all devices** – Enable this option to send the selected command to all connected clients simultaneously.
- Select desired options and click **Send Command(s).**

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-8.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-8.png)

### User Management

Navigate to **Users** page.

#### *Add User*

Click **Add User**

- Enter username
- Enter password
  - Minimum 8 characters; One uppercase letter; One lowercase letter; One number; One special character
- Confirm password
- Select Admin if applicable
- Click Add User

#### *Modify User*

- Click **Modify**
- Edit name, password, or role
- Click **Modify User**

#### *Delete User*

- Click **Delete**
- Confirm action

**Important:** An admin cannot delete or demote themselves.

#### *User Permissions*

| **Role** | **Access** |
| --- | --- |
| **Admin** | Full system access |
| **User** | Main, Data, Users (own password), JSON |

**Important:** Users cannot add or delete devices.

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-9.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-9.png)

### Network Settings

Navigate to **Network Settings**.

This section controls how the server connects to your local network.

#### *Network Configuration*

| **DHCP (Automatic IP)** Check Use DHCP.Click Update Network.   | **Static IP (Manual Setup)** Uncheck Use DHCP.Enter:IP AddressNetwork MaskDefault GatewayClick Update Network.   |
| --- | --- |

**Note:** Reconnect using the new IP after changes

#### *NTP Server (Time Sync)*

Keeps system time accurate.

- Enter NTP server (default: time.nist.gov).
- Click **Update NTP**.

#### *Time zone*

Sets local system time.

- Select your timezone.
- Click **Update Timezone**.

#### *HTTPS Certificates*

Manages secure web access.

- **Certificate Mode** – Select default or custom certificate
- **Upload Certificates** – Upload .**crt**and .**key**files (if provided by IT)
- **Download Cert** – Download current certificate
- **Force Renew** – Generate a new certificate

Click **Update Cert Settings** after changes.

### Communications Page – Database export and Radio Polling

The **Communications** page is used to configure radio polling and automatic database data export.

The server supports automatic export to:

- **PostgreSQL**
- **MySQL**

#### *Radio Polling*

Radio polling controls how often the server communicates with client devices.

- Configure the polling mode and interval as required.
- Enable automatic polling if continuous monitoring is needed.
- **Save** the settings.

**Recommendation:** Use default polling values unless optimization is required.

#### *Database Auto Export*

This feature allows the server to automatically send data to an external database.

- Enable **Database Auto Export**.
- Select the database type (PostgreSQL or MySQL).
  - Enter:
  - Host IP
  - Port
  - Database name
  - Username

  - Password
- Save the settings

[![](https://resources.linortek.com/wp-content/uploads/2026/05/image-10.png)](https://resources.linortek.com/wp-content/uploads/2026/05/image-10.png)

### Software Updates

Navigate to **Software Update**.

#### Steps:

- Click **Choose File**
- Select `.enc` update file
- Click **Apply Update**
- Wait for system to reinitialize

Do not power off during update.

### **Audit Log – Activity Tracking**

The **Audit Log** page records important system activities and user actions for security and troubleshooting purposes.

**Recorded Events:**

- User logins and logouts
- Password changes
- User account modifications
- Device additions and removals
- Configuration changes
- Software updates
- Command transmissions

### Help Page

The **Help** page provides quick reference information, downloadable resources, and technical support details.

| **Quick Tips** | Displays important reminders for system setup, operation, and maintenance |
| --- | --- |
| **User Manual** | Provides access to the complete installation and operation guide. Click Download PDF Manual to download the latest version |
| **Certificate Update Script** | Allows Windows users to automatically install security certificates. Download and run the script if required by your network administrator |
| **Support** | Displays official documentation links and technical support contact information |

## Reset iTrixx-LHM-S (Server) to Factory Settings

**Verify Power**

- Ensure the device is connected to **PoE power**.
- Locate the **LED indicators on the right side of the enclosure**.
- Confirm that both **Red and Green LEDs are solid**.

**Open the Enclosure**

- Remove the **four Phillips screws** securing the top lid.
- Carefully lift the lid to access the internal boards.

**Locate the Push Buttons**

- On the **top board**, locate the **three push-button switches**.
- The reset procedure uses:
  - **Button 1 – Top**

  - **Button 2 – Middle**

**Start the Reset Process**

- Press and **hold Button 1 (top)** for approximately **10 seconds**.
- The **Green LED will begin blinking twice per second**.
- Once the blinking starts, **release Button 1**.

**Confirm Reset**

- Press **Button 2 (middle)** **once**. Do **not hold** the button.
- The **Green LED will rapidly blink for about 5 seconds**, then:
  - Blink **twice per second for another 5 seconds**, then

  - Return to **solid Green**.

**Finish**

- When the **Green LED is solid again**, the factory reset is complete.
- Secure the lid**with the four screws**.

## Troubleshooting

| **Issue** | **Possible Cause** | **Solution** |
| --- | --- | --- |
| No data | Duplicate ID | Verify rotary switches |
| Offline client | No power, Weak signal, Wrong Key, Wrong ID | Ensure client is powered, Reposition antennas, Verify rotary switches, Verify AES Key configurations on the server |
| Cannot login | Wrong password | Reset via admin or reset to factory settings |
| No network connection | IP conflict | Check Network Settings |

## Support & Maintenance

- Keep Server’s firmware up to date
- Maintain ID documentation
- Inspect built in the server fan, clean with vacuum periodically
- Backup database regularly

## Appendix 1: Wiring the Client

![](https://resources.linortek.com/wp-content/uploads/2026/05/image-11-1030x766.png)